![NIBE-BIAWAR HK 200S Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/nibe-biawar/hk-200s/hk-200s_installation-and-operating-manual_1686586038.webp)
38
HK 200S
HK 200S-6
Technical documentation
AMS 10-6/ HBS 05-12 / HK 200S-6
Model
HK 200S-6
Model hot water heater
Air-water
Exhaust-water
Brine-water
Water-water
Type of heat pump
Yes
No
Low-temperature heat pump
Yes
No
Integrated immersion heater for additional heat
Yes
No
Heat pump combination heater
Average
Cold
Warm
Climate
Average (55 °C)
Low (35 °C)
Temperature application
EN14825 / EN16147
Applied standards
%
131
Š
s
Seasonal space heating energy efficiency
kW
5,3
Prated
Rated heat output
Declared coefficient of performance for space heating at part load and at
outdoor temperature Tj
Declared capacity for space heating at part load and at outdoor temperature
Tj
-
1,88
COPd
Tj = -7 °C
kW
4,7
Pdh
Tj = -7 °C
-
3,26
COPd
Tj = +2 °C
kW
2,8
Pdh
Tj = +2 °C
-
4,72
COPd
Tj = +7 °C
kW
1,8
Pdh
Tj = +7 °C
-
6,47
COPd
Tj = +12 °C
kW
2,7
Pdh
Tj = +12 °C
-
1,88
COPd
Tj = biv
kW
4,7
Pdh
Tj = biv
-
1,77
COPd
Tj = TOL
kW
4,1
Pdh
Tj = TOL
-
COPd
Tj = -15 °C (if TOL < -20 °C)
kW
Pdh
Tj = -15 °C (if TOL < -20 °C)
°C
-10
TOL
Min. outdoor air temperature
°C
-7
T
biv
Bivalent temperature
-
COPcyc
Cycling interval efficiency
kW
Pcych
Cycling interval capacity
°C
58
WTOL
Max supply temperature
-
0,99
Cdh
Degradation coefficient
Additional heat
Power consumption in modes other than active mode
kW
1,2
Psup
Rated heat output
kW
0,007
P
OFF
Off mode
kW
0,012
P
TO
Thermostat-off mode
Electric
Type of energy input
kW
0,012
P
SB
Standby mode
kW
0
P
CK
Crankcase heater mode
Other items
m
3
/h
2 526
Rated airflow (air-water)
Variable
Capacity control
m
3
/h
Nominal heating medium flow
dB
35 / 51
L
WA
Sound power level, indoors/outdoors
m
3
/h
Brine flow brine-water or water-water heat
pumps
kWh
3 248
Q
HE
Annual energy consumption
Chapter 11 |
Technical data