16
HK 200S
HK 200S-6
Connections
Mounting requirements
General information
NIBE SPLIT can be connected in many various ways.
More information on connections to be found at web-
site www.nibe.eu.
Chapter 4 |
Pipe connections
AMS 10-6
AMS 10-8
AMS 10-12
Max pressure, climate system
0.25 MPa (2.5 Bar)
Highest recommended supply/return temperature at dimensioned out
-
door temperature
55/45 °C
Max temperature in HK 200S / HK 200S-6
+65 °C
Max flow line temperature with compressor
+58 °C
Min supply temperature cooling
+7 °C
Max supply temp. cooling
+25 °C
Min volume, climate system during heating, cooling*
50 l
80 l
Min volume, climate system during under floor cooling*
80 l
100 l
Max flow, climate system
0.38 l/s
0.57 l/s
Min flow, climate system, 100% circulation pump speed (defrosting
flow)
0.19 l/s
0.29 l/s
Min flow, heating system
0.12 l/s
0.15 l/s
Min flow, cooling system
0.16 l/s
0.20 l/s
* Regards circulating volume
External circulation pump must be used when the pressure drop in the system is greater than the available external pressure.
In such cases, a bypass line with non-return valve must be installed.
Overflow valve must be used if min. system flow cannot be guaranteed.