Performance
Outdoor module / HK 200S-6
AMS 10-6 / SMO
/ HK 200S-6
AMS 10-8 / SMO
/ HK 200S-6
AMS 10-12 / SMO
/ HK 200S-6
Heating
Outd. temp. /
Supply temp.
Nominal
Nominal
Nominal
Output data according to EN14511 ΔT5K
Specified/supplied power/COP (kW/kW/-)
7/35°C (floor)
2,67/0,5/5,32
3,86/0,83/4,65
5,21/1,09/4,78
2/35°C (floor)
2,32/0,55/4,2
5,11/1,36/3,76
6,91/1,79/3,86
7/45°C
2,28/0,63/3,62
3,70/1,00/3,70
5,00/1,31/3,82
2/45°C
1,93/0,67/2,88
5,03/1,70/2,96
6,80/2,24/3,04
Cooling
Outd. temp. /
Supply temp.
Max.
Max.
Max.
Output data according to EN14511 ΔT5K
Specified/supplied power/EER
27/7°C
5,87/1,65/3,56
7,52/2,37/3,17
9,87/3,16/3,13
27/18°C
7,98/1,77/4,52
11,20/3,20/3,50
11,70/3,32/3,52
35/7°C
4,86/1,86/2,61
7,10/2,65/2,68
9,45/3,41/2,77
35/18°C
7,03/2,03/3,45
9,19/2,98/3,08
11,20/3,58/3,12
Max. operating current and recommended fuse rating
when connected 3x400 V
Unit
HK 200S-6
+AMS 10-6
HK 200S
+AMS 10-8
HK 200S-6
+AMS 10-12
Max. operating current compressor
A
16
16
20
Max operating current heat pump including 3 kW immersion heat
-
er , compressor working and enabled contactor K1
(Recommended fuse rating)
A
16 (20)
16 (20)
20 (20)
Max operating current heat pump including 6 kW immersion heat
-
er, compressor working and enabled contactor K1+K2
(Recommended fuse rating)
A
16 (20)
16 (20)
20 (20)
Max operating current heat pump including 9 kW immersion heat
-
er, compressor working and enabled contactor K1+K2 +K3
(Recommended fuse rating)
A
20 (20)
20 (20)
20 (20)
Max operating current 9 kW immersion heater, compressor not
working and enabled contactor K1+K2 +K3
(Recommended fuse rating)
A
20 (20)
20 (20)
20 (20)
Max. operating current and recommended fuse rating
when connected 1x230 V
Unit
HK 200S-6
+AMS 10-6
HK 200S
+AMS 10-8
HK 200S-6
+AMS 10-12
Max. operating current compressor
A
16
16
20
Max operating current heat pump including 3 kW immersion heat
-
er , compressor working and enabled contactor K1
(Recommended fuse rating)
A
29 (32)
29 (32)
33 (40)
Max operating current heat pump including 6 kW immersion heat
-
er, compressor working and enabled contactor K1+K2
(Recommended fuse rating)
A
42 (50)
42 (50)
46 (50)
Max operating current heat pump including 9 kW immersion heat
-
er, compressor working and enabled contactor K1+K2 +K3
(Recommended fuse rating)
A
55 (63)
55 (63)
59 (63)
Max operating current 9 kW immersion heater, compressor not
working and enabled contactor K1+K2 +K3
(Recommended fuse rating)
A
39 (40)
39 (40)
39 (40)