Temperature sensor, hot water loading
DHW temperature sensor
Temperature sensor, hot water loading (BT6) is locat-
ed at the bottom part on the DHW heater.
The sensor must be connected - for SMO 20 to
clamps X2:5 and X2:6, while for SMO 40 to clamps
X6:7 and X6:8. Use a two-wire cable with the cross-
section of at least 0.5 mm².
Temperature sensor in the top part of the DHW heater
(BT7) indicates water temperature at the top part of
the tank.
The sensor must be connected - for SMO 20 to
clamps X2:4 and X2:6, while for SMO 40 to clamps
X6:15 and X6:16.Use a two-wire cable with the cross-
section of at least 0.5 mm².