Installation and operating manual
Indoor unit
Cooperating with air
heat pumps
HK 200S
HK 200S-6
Страница 1: ...16 10 2018 25959 Installation and operating manual Indoor unit Cooperating with air heat pumps HK 200S HK 200S 6 HK 200S 6...
Страница 2: ...SMO 20 SMO 40 In order to temporarily increase hot water volume first turn the control knob to mark menu 2 icon presenting water drop and press the OK button twice More information to be found in sect...
Страница 3: ...formation__________________19 Connections________________________20 Settings ___________________________28 6 Start up and regulation _____ 29 Preparations _______________________29 Filling and venting...
Страница 4: ...ised children Rights to implement design changes are reserved NIBE BIAWAR 2018 This manual contains installation and maintenance proce dures for specialists The serial number is located at the top of...
Страница 5: ...Power supply Communication connection Circuit fuses Fuses internal module Building fuses Temperature sensor outdoor Room sensor Energy meter Emergency switch Switch differential Thermostat emergency...
Страница 6: ...st be set on a solid wa terproof base that would keep the weight of the indoor unit The regulated legs of the heat pump allow for levelling and stable setting of the device Because HK 200S HK 200S 6 i...
Страница 7: ...S HK 200S 6 3 Indoor module structure HK 200S HK 200S 6 Chapter 3 Indoor module structure XL10 XL11 QN12 QN10 GP12 EP2 CM1 EB1 XL4 XL13 XL14 XL3 XL2 XL1 BP4 EB15 BT15 BT71 BT6 EB2 BT64 BT63 BT7 BT12 B...
Страница 8: ...perature sensor heating medium re turn BT6 Temperature sensor hot water loading BT7 Temperature sensor top of the hot water heater BT12 Temperature sensor condenser outlet BT15 Temperature sensor liqu...
Страница 9: ...wing The ini tial pressure of 0 5 bar 5 mvp shall mean maximum permissible height difference of 5 m If the standard initial pressure in the diaphragm ex pansion vessel is too low it can be raised by f...
Страница 10: ...AMS 10 outdoor unit provides heat for heating the do mestic hot water and supplying the heating system while using free energy in the outdoor air efficiently operating within the range of low tempera...
Страница 11: ...problem The device can be leveled using regulated legs Pipes must be led in such a way that they are not adjacent to the bedroom or living room Remember to leave about 800 mm free space at the front a...
Страница 12: ...mm XL3 Connection cold water 22 mm XL4 Connection hot water 22 mm XL5 Connection circulation 15 mm XL10 Connection cooling 22 mm XL11 Connection safety group 22 mm manometer XL13 Liquid cooling mediu...
Страница 13: ...order to prevent air sockets the overflow pipe must be slanted at the entire length from the safety valve and must be se cured against freezing When connecting to the installation where all heaters ha...
Страница 14: ...R410A tool mm B using a con ventional tool mm 9 52 0 0 0 5 0 7 1 3 15 88 6 35 1 0 1 5 12 7 External diameter cop per pipe mm Torque Nm Tighten ing angle Recom mended tool length mm 6 35 14 18 45 60 1...
Страница 15: ...es must undergo a pressure test and leakage test after completing the in stallation process according to applicable regulations Use nitrogen only for system compression and rinsing ADVICE In order to...
Страница 16: ...ply temperature cooling 7 C Max supply temp cooling 25 C Min volume climate system during heating cooling 50 l 80 l Min volume climate system during under floor cooling 80 l 100 l Max flow climate sys...
Страница 17: ...ernal unit to operate individu ally without an external unit The installation of the mixing valve is necessary if factory settings are changed in a way where the temperature can exceed 60 C When chang...
Страница 18: ...nel down to access the hydraulic connections 3 Remove the plug from the circulation pipe XL5 4 Install the elbow facing the rear housing on the circulation pipe 5 Connect the pipe to the elbow with th...
Страница 19: ...ront wall IMPORTANT As long as the heating circuits have not been filled with the heating medium and if the central heating system has not been vented the switch SF1 in SMO cannot be set in positions...
Страница 20: ...erferences do not lay unshielded communication and or signal cables to external con tacts at the distances lower than 20 cm from high voltage cables Power supply connection Temperature limiter Tempera...
Страница 21: ...re connect ing the devices with a cable The cabling must be fixed in such a way so that the terminal block is not under tension The terminal without insulation is 8 mm long AMS 10 6 AMS 10 8 AMS 10 12...
Страница 22: ...40 to clamps X4 1 A X4 2 B and X4 3 GND according to the drawing Connect the control signal GP12 for SMO 20 to clamps X2 1 PWM and X2 2 GND while for SMO 40 to clamps X4 8 and X4 7 according to the dr...
Страница 23: ...wire cable with the cross section of at least 0 5 mm Temperature sensor in the top part of the DHW heater BT7 indicates water temperature at the top part of the tank The sensor must be connected for...
Страница 24: ...e isolation valve QN10 Temperature sensor on the pipeline downstream the heating module BT63 must be connected in SMO 20 to clamps X2 9 and X2 10 while in SMO 40 to AUX clamps e g X6 13 and X6 14 and...
Страница 25: ...n the heat pump see SMO installation manual Temperature sensor on return pipeline BT71 must be connected to SMO 20 at AUX output while in SMO 40 to clamps X6 15 and X6 16 at the input card AA3 Turning...
Страница 26: ...2 All auxiliary heaters can be blocked by connecting the potential free relay function to clamp X2 of the program controlled input see SMO manual Chapter Electrical connections section Optional Connec...
Страница 27: ...L N 1 1 0 2 3 4 PE 1 2 3 4 LEK AA3 X7 4 1 5 1 6 1 7 1 SMO Externt L L N N PE PE External RC HY 20 AA2 X4 LEK L N 1 1 0 2 3 4 PE AA2 X4 HK200S HK200S 6isequippedwithaterminalblockin communication card...
Страница 28: ...ary functions are active The volume of domestic hot water is limited Load sensor has not been connected Constant temperature in the supply pipeline more information to be found in the Chapter w Emerge...
Страница 29: ...ating sys tem 2 Set all the isolation valves in the position allowing for flow in all circuits 3 Open the valve for filling the heating installation and fill it with the heating medium 4 Close the ven...
Страница 30: ...r for example before the installation of the heat pump Enter menu 5 2 2 System setting and turn the heat pump off IMPORTANT Select auto or manual operating mode when the in door module is to be used a...
Страница 31: ...o be found in the Help menu or in the operating manual Advanced settings These settings are not available to the end user This menu will be visible if the Back button is pressed in the start menu for...
Страница 32: ...water connection In order to make maintenance of the heating system easier the system must first be emptied using the fill ing valve 1 Connect the hose to the external drain valve sys tem 2 Open the...
Страница 33: ...displayed Detailed information regarding distorted heat comfort can be found in the manual for SMO 20 or SMO 40 in the chapter with the same title Accessories that can be used depend on the applied C...
Страница 34: ...34 HK 200S HK 200S 6 11 Technical data Dimensions and layout of connections 600 5 610 5 300 156 93 5 92 5 87 63 55 65 155 44 151 7 20 40 1589 115 Chapter 11 Technical data...
Страница 35: ...mpressor Twin Rotary Max fan flow heating nominal m3 h 3 000 4 380 Fan rating W 86 Defrosting Reversing Drain pan heater W Integrated 100 Integrated 120 Breaking value high pressure MPa bar 4 15 41 5...
Страница 36: ...actor K1 Recommended fuse rating A 16 20 16 20 20 20 Max operating current heat pump including 6 kW immersion heat er compressor working and enabled contactor K1 K2 Recommended fuse rating A 16 20 16...
Страница 37: ...ng cold kWh 2 694 4 610 6 264 8 844 7 798 11 197 Annual energy consumption space heating warm climate kWh 872 1 398 1 879 2 333 2 759 3 419 Seasonal space heating energy efficiency cold climate 143 11...
Страница 38: ...Pdh Tj 2 C 4 72 COPd Tj 7 C kW 1 8 Pdh Tj 7 C 6 47 COPd Tj 12 C kW 2 7 Pdh Tj 12 C 1 88 COPd Tj biv kW 4 7 Pdh Tj biv 1 77 COPd Tj TOL kW 4 1 Pdh Tj TOL COPd Tj 15 C if TOL 20 C kW Pdh Tj 15 C if TOL...
Страница 39: ...COPd Tj 2 C kW 3 9 Pdh Tj 2 C 4 42 COPd Tj 7 C kW 2 6 Pdh Tj 7 C 5 93 COPd Tj 12 C kW 3 7 Pdh Tj 12 C 1 83 COPd Tj biv kW 6 6 Pdh Tj biv 1 86 COPd Tj TOL kW 5 9 Pdh Tj TOL COPd Tj 15 C if TOL 20 C kW...
Страница 40: ...Tj 2 C 4 61 COPd Tj 7 C kW 3 5 Pdh Tj 7 C 6 25 COPd Tj 12 C kW 5 0 Pdh Tj 12 C 1 90 COPd Tj biv kW 9 2 Pdh Tj biv 1 92 COPd Tj TOL kW 8 1 Pdh Tj TOL COPd Tj 15 C if TOL 20 C kW Pdh Tj 15 C if TOL 20 C...
Страница 41: ...ions 3 x 400 V F1 20A 5G2 5mm 2 K1 K2 3x1 5kW 3x1 5kW Immersion heater F2 10A X2 2 3 L N PE 2 3 L N PE AMS10 6 5G2 5mm 3G1 5mm 2 2 L N PE L N PE SMO F3 98 8 C N X3 L N N L PE AMS10 2 AMS10 3 K3 Supply...
Страница 42: ...TITANIUM ANODE X3 2 1 2 1 AMS10 2 AMS10 3 OPTION KVR KIT OPTION RCBO FOR KVR KIT 2 1 2 1 1 2 2 1 N N FB1 X100 XJ15 brown white XJ12 XJ3 X1 1 2 3 1 2 1 2 1 2 1 2 3 4 X6 1 2 3 4 5 6 A B GND A B GND 6 5...
Страница 43: ...MERGENCY L K1 N X2 PE Brown Black N Brown Black N T1 5 80 C N X3 M 1 GP12 K2 K1 M 1 QN12 M 1 QN10 BT6 X1 BT6 BT7 BT7 BT63 BT63 BT25 BT25 BT71 BT71 BT7 BT63 BT25 BT71 PWM GND K3 K3 BT64 BT64 BT64 BT6 C...