5 - REMOTE CONTROL MANAGEMENT
Default: no transmitter associated / remote programming enabled
With this procedure it is possible to:
- Associate a compatible transmitter
- Delete the programmed transmitters
PROCEDURE
STEP 1
Keep pressing and releasing the SEL key until the
«Code» LED comes on.
STEP 2
Press and release the SET button to confirm.
The «Code» LED flashes.
STEP 3
By pressing and releasing the SEL key, select the value
corresponding to the setting you want, according to the
following table.
DISPLAY NO.
DESCRIPTION
1
Save remote control
8
Not used
9
Deleting all remote controls
E
Exit
STEP 4a
Press and release the SET key and
the LED on the display flashes, then
send an “UP” command with the
transmitter to be saved.
The display will show:
S = remote control saved
P = remote control already saved
r = remote control not recognised
F = remote control memory full
Wait 20 seconds or press the SEL
button until an E (exit) appears on
the display and confirm with the
SET button.
STEP 4b
Not used
STEP 4c
Press and hold the SET key (about
5 seconds) to confirm the deletion.
The control unit will beep.
Wait 20 seconds or press the SEL
button until an E (exit) appears on
the display and confirm with the
SET button.
1 (save remote control)
8
9 (deleting)
7
SOLE
NEVE
TEMP.
PIOGGIA
VENTO
T.MOT.
CODE
MOT.TYPE
SEL
Sens.
Rit. Neve
SET
SOLE
NEVE
TEMP.
PIOGGIA
VENTO
T.MOT.
CODE
MOT.TYPE
SEL
Sens.
Rit. Neve
SET
SOLE
NEVE
TEMP.
PIOGGIA
VENTO
T.MOT.
CODE
MOT.TYPE
SEL
Sens.
Rit. Neve
SET
Содержание PRG-M24
Страница 15: ...15...