background image

4 - SETTING OPERATING MODE

Default: 1 motor, manual

This procedure is used to set the number of motors connected and the type of control.

There can be 1 or 2 motors (synchronised operation).

Operation via radio can be:

MANUAL the motor moves in the direction selected until the transmitter key is held down  

NOTE: sensors not enabled

AUTOMATIC each time the key is pressed the motor moves 30% of the total travel in the selected direction 

VENETIAN press and release the key and the motor moves slightly in the selected direction, press and hold (>2sec) and 

it moves fully in the selected direction

OPEN/STOP/CLOSE each time the key is pressed the motor moves fully in the selected direction

Note: 

if automatic, Venetian or OPEN/STOP/CLOSE operation is set it will be necessary to notify the control unit of the 

working time of the motor(s) with the procedure in paragraph 6 every time that the parameter is changed

PROCEDURE

STEP 1 

Keep pressing and releasing the SEL key until the 

«Mot. Type» LED comes on.

The display shows the current setting.

STEP 2 

Press and release the SET button to confirm. The LED on 

the display flashes.

STEP 4 

Press and release the SET button to confirm.

Wait 20 seconds or press the SEL button until  

a horizontal line appears on the display.

Note: 

if automatic or Venetian operation is set it will be necessary to notify the control unit of the 

working time of the motor(s) with the procedure in paragraph 6 every time that the parameter is 

changed

STEP 3 

By pressing and releasing the SEL key, select the value 

corresponding to the setting you want, according to the 

following table.

DISPLAY NO.

DESCRIPTION

1

1 motor manual operation

2

1 motor automatic operation

3

1 motor Venetian operation

4

1 motor Open/Stop/Close operation

5

2 motors manual operation

6

2 motors automatic operation

7

2 motors Venetian operation

8

2 motors Open/Stop/Close operation

E

Exit

6

SOLE

NEVE

TEMP.

PIOGGIA

VENTO

T.MOT.

CODE

MOT.TYPE

SEL

Sens.

Rit. Neve

SET

SOLE

NEVE

TEMP.

PIOGGIA

VENTO

T.MOT.

CODE

MOT.TYPE

SEL

Sens.

Rit. Neve

SET

SOLE

NEVE

TEMP.

PIOGGIA

VENTO

T.MOT.

CODE

MOT.TYPE

SEL

Sens.

Rit. Neve

SET

SOLE

NEVE

TEMP.

PIOGGIA

VENTO

T.MOT.

CODE

MOT.TYPE

SEL

Sens.

Rit. Neve

SET

Содержание PRG-M24

Страница 1: ...nit for the automation of outdoor pergolas with rotating slats and board for optional LED management 24 Vdc power supply Output for 1 or 2 x 24 VDC motors max 120 W each 433 92 MHz receiver for radio...

Страница 2: ...TING OPERATING MODE page 6 5 REMOTE CONTROL MANAGEMENT page 7 6 SETTING WORKING TIME OF MOTORS page 8 7 MANAGEMENT OF SENSORS 7 1 SETTING WIND SENSOR 7 2 SETTING RAIN SENSOR 7 3 SETTING TEMPERATURE SE...

Страница 3: ...pply Input 24 Vdc Type of load Output 1 or 2 x 24 VDC motors Max load power Output Max 120 W per output Number of programmable transmitters 150 Receiver frequency RF 433 920MHz Operating temperature 1...

Страница 4: ...ed power supply units of the correct size for the load NOTE Connect maximum 120 W per output Operation of the inputs is manual The control unit can manage either the wind sensor wind gauge or the sun...

Страница 5: ...ith the SEL key the display s LED flashes Confirm the selected value by pressing the SET key again the display s LED stays on After 20 seconds the control unit goes back into stand by LED DESCRIPTION...

Страница 6: ...LED comes on The display shows the current setting STEP 2 Press and release the SET button to confirm The LED on the display flashes STEP 4 Press and release the SET button to confirm Wait 20 seconds...

Страница 7: ...and the LED on the display flashes then send an UP command with the transmitter to be saved The display will show S remote control saved P remote control already saved r remote control not recognised...

Страница 8: ...T LED comes on STEP 2 Press and release the SET button to confirm The LED on the display flashes STEP 3 By pressing and releasing the SEL key you can select value 0 on the display STEP 4 Press and rel...

Страница 9: ...essing and releasing the SEL key select the value corresponding to the setting you want according to the following table DISPLAY NO DESCRIPTION d Wind sensor disabled 0 Wind sensor test 1 Wind sensor...

Страница 10: ...g the SEL key select the value corresponding to the setting you want according to the following table DISPLAY NO DESCRIPTION d Rain sensor disabled 0 Rain sensor test y Rain sensor enabled E Exit STEP...

Страница 11: ...e display flashes STEP 3 By pressing and releasing the SEL key select the value corresponding to the setting you want according to the following table DISPLAY NO DESCRIPTION d Temperature sensor disab...

Страница 12: ...and release the SET button to confirm The LED on the display flashes STEP 3 By pressing and releasing the SEL key select the value corresponding to the setting you want according to the following tabl...

Страница 13: ...button to confirm The LED on the display flashes STEP 3 By pressing and releasing the SEL key select the value corresponding to the setting you want according to the following table DISPLAY NO DESCRI...

Страница 14: ...nit with the factory parameters PROCEDURE STEP 1 Press SET and SEL at the same time until all the red LEDs come on When the reset is completed the control unit will beep 3 times in confirmation 14 SOL...

Страница 15: ...15...

Страница 16: ...V2 0 Nexta Tech company brand of Team srl via G Oberdan 90 33074 Fontanafredda PN Italy Ph 39 0434 998682 Email info nexta tech com Web www nexta tech com...

Отзывы: