3 - SETTING UP CONTROL UNIT
The following functions are the default settings for the control unit:
- Manual management of a motor Ouvrir / Arrêter / Fermer
- Wired inputs enabled manually (operation cannot be set)
- No transmitter programmed
- No sensor enabled
Some functions can be set via the keys, LEDs and trimmers.
USE OF PROGRAMMING INTERFACE:
By using the SEL and SET keys you can move around inside the menus and change the various functions.
Each time you press the SEL key you move between LEDs. Each LED indicates a function (see following table for
specific functions).
To select the parameter press the SET key and then select the value that appears on the display with the SEL key (the
display’s LED flashes).
Confirm the selected value by pressing the SET key again (the display’s LED stays on).
After 20 seconds the control unit goes back into stand-by.
LED
DESCRIPTION
DEFAULT
PARAGRAPH
Motor type
Selecting motors and operating mode
1 motor, manual
3.1
Code
Remote control management
No associated remote control
3.2
T.motor
Setting motor time
No motor time
3.3
Wind
Management of wind sensor
Disabled
3.4
Rain
Management of rain sensor
Disabled
3.5
Temperature Management of temperature sensor
Disabled
3.6
Snow
Management of snow sensor
Disabled
3.7
Sun
Management of sun sensor
Disabled
3.8
After making the connections automation is already in operation with manual commands via wire.
Display
Display led
SEL key
VR1 trimmer to adjust obstacle sensitivity
VR2 trimmer to adjust duration of snow
contact closure
SET key
5