Страница 1: ...nit for the automation of outdoor pergolas with rotating slats and board for optional LED management 24 Vdc power supply Output for 1 or 2 x 24 VDC motors max 120 W each 433 92 MHz receiver for radio...

Страница 2: ...TING OPERATING MODE page 6 5 REMOTE CONTROL MANAGEMENT page 7 6 SETTING WORKING TIME OF MOTORS page 8 7 MANAGEMENT OF SENSORS 7 1 SETTING WIND SENSOR 7 2 SETTING RAIN SENSOR 7 3 SETTING TEMPERATURE SE...

Страница 3: ...pply Input 24 Vdc Type of load Output 1 or 2 x 24 VDC motors Max load power Output Max 120 W per output Number of programmable transmitters 150 Receiver frequency RF 433 920MHz Operating temperature 1...

Страница 4: ...ed power supply units of the correct size for the load NOTE Connect maximum 120 W per output Operation of the inputs is manual The control unit can manage either the wind sensor wind gauge or the sun...

Страница 5: ...ith the SEL key the display s LED flashes Confirm the selected value by pressing the SET key again the display s LED stays on After 20 seconds the control unit goes back into stand by LED DESCRIPTION...

Страница 6: ...LED comes on The display shows the current setting STEP 2 Press and release the SET button to confirm The LED on the display flashes STEP 4 Press and release the SET button to confirm Wait 20 seconds...

Страница 7: ...and the LED on the display flashes then send an UP command with the transmitter to be saved The display will show S remote control saved P remote control already saved r remote control not recognised...

Страница 8: ...T LED comes on STEP 2 Press and release the SET button to confirm The LED on the display flashes STEP 3 By pressing and releasing the SEL key you can select value 0 on the display STEP 4 Press and rel...

Страница 9: ...essing and releasing the SEL key select the value corresponding to the setting you want according to the following table DISPLAY NO DESCRIPTION d Wind sensor disabled 0 Wind sensor test 1 Wind sensor...

Страница 10: ...g the SEL key select the value corresponding to the setting you want according to the following table DISPLAY NO DESCRIPTION d Rain sensor disabled 0 Rain sensor test y Rain sensor enabled E Exit STEP...

Страница 11: ...e display flashes STEP 3 By pressing and releasing the SEL key select the value corresponding to the setting you want according to the following table DISPLAY NO DESCRIPTION d Temperature sensor disab...

Страница 12: ...and release the SET button to confirm The LED on the display flashes STEP 3 By pressing and releasing the SEL key select the value corresponding to the setting you want according to the following tabl...

Страница 13: ...button to confirm The LED on the display flashes STEP 3 By pressing and releasing the SEL key select the value corresponding to the setting you want according to the following table DISPLAY NO DESCRI...

Страница 14: ...nit with the factory parameters PROCEDURE STEP 1 Press SET and SEL at the same time until all the red LEDs come on When the reset is completed the control unit will beep 3 times in confirmation 14 SOL...

Страница 15: ...15...

Страница 16: ...V2 0 Nexta Tech company brand of Team srl via G Oberdan 90 33074 Fontanafredda PN Italy Ph 39 0434 998682 Email info nexta tech com Web www nexta tech com...

Отзывы: