![New York Air Brake IP-235 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/new-york-air-brake/ip-235/ip-235_instruction-manual_1678304019.webp)
Knorr-Bremse Group
Page 19 / 40
Copyright 2015© NYAB. All rights reserved, including industrial property rights applications.
NYAB retains any power of disposal, such as copying and transferring.
Locomotive Cab Display Module (LCDM)
Maintenance Manual
Doc. No. IP-235
03
4.4.2.3
Protection Category
Housing
IP54 (with attached wiring and unused plugs covered with a cap)
Front
IP65 (when installed)
4.4.2.4
Other
Front Membrane polyester
Display Cover
scratch-resistant toughened glass panel,
0.16" (4 mm) thick
The glass panel is inserted flush with the front membrane.
It is an anti-glare design with a glare value of 100.
4.4.3
Electrical
4.4.3.1
Power Supply
4.4.3.1.1
LCDM 782340
Connection
reverse polarity protected
Nominal voltage
74VDC (25VDC...135VDC)
Power consumption
typ. 20 W (without heating)
max. 30 W
max. starting current
25 A (30 µs.. .-50 µs)
Dielectric strength
Supply voltage primary against secondary / housing: 1,500VAC
Galvanically isolated circuits against housing: 2,000VAC (RS422),
1,000VAC (Ethernet, RS232)
Non galvanically isolated circuits against housing:
due to internal connection between secondary 0V and housing, this dielectric
strength is not given
4.4.3.1.2
LCDM 782342
Connection
reverse polarity protected
Nominal voltage
110VDC (66VDC...154VDC)
Power consumption
typ. 20 W (without heating)
max. 30 W
max. starting current
25 A (30 µs.. .-50 µs)
Dielectric strength
Supply voltage primary against secondary / housing: 1,500V AC
Galvanically isolated circuits against housing: 2,000V AC (RS422)
1,000V AC (Ethernet, RS232)
Non galvanically isolated circuits against housing:
due to internal connection between secondary 0V and housing, this dielectric
strength is not given.