3.1
General Safety Awareness
To prevent physical injury or death, all personnel directly or indirectly involved with the ope-
ration of the equipment described in this manual must conform to the following:
3.1.1
Observe all rules and regulations of the railroad where the equipment is being used.
Whenever there is a conflict between the instructions in this manual and the instructions of
the user railroad, the rules and regulations of the user railroad will govern.
3.1.2
When performing any operation of the equipment while it is on the vehicle (on vehicle test,
etc.) special precautions must be taken to ensure that vehicle movement will not occur which
could result in injury to personnel and/or damage to equipment. Make sure the handbrake is
applied and that the wheels are chocked to prevent vehicle from moving.
3.1.3
Shut off power and open airbrake breaker whenever continuity is to be checked or when
handling equipment connections. When shutting off power by means of knife or switch.
3.1.3.1
Attach an approved WARNING tag to the open breaker
3.1.4
Personal eye protection must be worn when doing any work to protect eyes from possible
injury.
3.1.5
Where fasteners removed from the equipment are not satisfactory for reuse, care must be
taken to select replacements that match the originals. Mismatched or incorrect fasteners can
result in equipment damage or malfunction, or possible personal injury.
3 Safety
High Voltages (AC and/or DC) are present. Always exercise extreme
care when working in close proximity to electrically energized appa-
ratus or when making current measurments. To prevent receiving
electrical shock when performing electrical tests, hands must be
clear of electrical components, contacts, and housing. There must
be no bodily contact with the work area.
Failure to comply with these instructions may lead to irreversible
physical injuries which may have fatal consequences.
Ensure that power and/or switches are turned off prior to making any
electrical connections/disconnections.
Failure to comply with these instructions may lead to irreversible
physical injuries which may have fatal consequences.