![Netscout aircheck G2 Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/netscout/aircheck-g2/aircheck-g2_user-manual_1674708114.webp)
All AirCheck G2 Settings
101
AutoTest Settings
The AutoTest Settings screen allows you to configure the
following settings:
Channel Scan Cycles
— Allows you to specify the number of
times that the channels are scanned during an AutoTest. The
default value is 1, but you can set it to any value between 1
and 10, using the left or right arrow buttons.
Rogue AP Test
— Allows you to specify whether AutoTest
identifies and lists APs which have been user configured with
an Authorization Class of Flagged or Unauthorized. You can
view and change an AP's Authorization Class from its Details
screen.
Network Tests
— Allows you to include or exclude
configured network tests as part of AutoTest, by selecting the
corresponding boxes for the networks you want to test.
NOTE:
In order to see a list of networks on the
AutoTest
Settings
screen, you must have the networks configured
already. You can add networks and APs in the
Settings
menu
or by selecting
Connect
from a
Network
or
AP Details
screen.
See “Entering Network Security Credentials,” page 49.
How to: Configure AutoTest settings
1
Set the
Channel Scan Cycles
.
2
Decide to include or exclude
Network Tests
. If you
decide to include Network Tests, then select the boxes
for the individual networks to be tested.
3
Touch
Apply
to save your changes.
iPerf Settings
The iPerf Settings screen controls aspects of the iPerf Test
feature.
Protocol
— Touch the drop-down button to switch between
the TCP and UDP protocols for iPerf testing. The default is
TCP.
Port
— Touch the Port field to enter a different port number.
Touch DONE to save the new port number. To restore the
default port number, on the Port screen, press the backspace
key on the virtual keyboard to clear the entry field, and then
press DONE.
Test Duration (sec.)
— Shows the selected duration for the
entire iPerf test run, with half of the time for the upload
portion and half for the download portion of the test. Touch
the drop-down button to select a different test duration. The
default iPerf duration is 20 seconds.
Accessory Battery Type
— Touch the drop-down button to
change the battery type to match the batteries in the
NETSCOUT Test Accessory you use to conduct iPerf Tests. This
setting allows the AirCheck G2 to display the battery level on