3. Click the Hardware tab.
4. In the Hardware pane of the Array Management Window, highlight Controller A, Port 1.
5. On the Array Management Window, from the Hardware menu, select Controller > Configure >
Configure Management Ports:
6. Change the IP address of Controller A, Port 1 to the management IP address, gateway, and subnet
mask by doing the following:
a. From the Speed and duplex mode drop-down list, select Auto-negotiate.
After you select Auto-negotiate, make sure that your Ethernet switch is also set to Auto-
negotiate. Connectivity issues might occur if automatic negotiation is selected in SANtricity
Storage Manager but not set for the Ethernet switch.
b. Depending on the format of your network configuration, select either Enable IPv4 or Enable
IPv6, or select both boxes.
c. Select Specify configuration, and change the IP address of Controller A, Port 1 to a routable
management IP address, gateway, and subnet mask.
d. Click OK.
7. After the change, ping the IP address using an external laptop, not the service laptop.
It might take a few minutes to get a response to the ping.
8. If the ping returns the IP data, disconnect the Ethernet cable from your service laptop, and
reconnect the cable from the controller to the management network.
9. In SANtricity Storage Manager, remove the newly added storage array and add it again using the
new IP addresses of Port 1.
10. Optionally, rename the controller by completing the following steps:
a. From the Enterprise Management Window, right-click the controller name and select
Rename.
Installing the appliance hardware | 33