Cabling the appliance
You must connect the two controllers to each other with SAS interconnect cables, connect the
management ports to the appropriate management network, and connect the 10 GbE ports on the
E5600SG controller to the Grid network and optional Client network for StorageGRID Webscale.
About this task
When connecting the cables, refer to the following diagram, which shows the E2700 controller on the
top and the E5600SG controller on the bottom. The diagram shows the SG5660 model; the
controllers in the SG5612 model are side by side instead of stacked.
Item
Port
Type of port
Function
1
Management port 1 on
the E2700 controller
1-Gb (RJ-45) Ethernet
Connects the E2700 controller to the
network where SANtricity Storage
Manager is installed.
2
Management port 2 on
the E2700 controller
1-Gb (RJ-45) Ethernet
Connects the E2700 controller to a
service laptop during installation.
3
Two SAS interconnect
ports on each
controller, labelled Ch
1 and Ch 2
E2700 controller:
mini-SAS-HD
E5600SG controller:
mini-SAS
Connect the two controllers to each
other.
4
Management port 1 on
the E5600SG
controller
1-Gb (RJ-45) Ethernet
Connects the E5600SG controller to the
Admin network for StorageGRID
Webscale.
5
Management port 2 on
the E5600SG
controller
1-Gb (RJ-45) Ethernet
Connects the E5600SG controller to a
service laptop during installation.
6
Four network ports on
the E5600SG
controller
10-GbE (optical)
Connect the E5600SG controller to the
Grid network and to the Client network
(if used) for StorageGRID Webscale.
The ports can be bonded together to
provide redundant paths to the
controller.
Installing the appliance hardware | 23