![NetApp StorageGRID SG5600 Series Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/netapp/storagegrid-sg5600-series/storagegrid-sg5600-series_hardware-installation-and-maintenance-manual_1669964031.webp)
To diagnose other issues, you might want to look at these resources:
•
To see all other hardware and environmental diagnostic information, see the E-Series operating
system hardware diagnostics.
This includes looking for hardware issues such as power, temperature, and disk drives. The
appliance relies on the E-Series operating system to monitor all platform environmental statuses.
•
To determine firmware and driver issues, look at the link lights on the SAS and network ports.
For details, see the E-Series E5600 documentation.
General boot-up codes
During boot-up or after a hard reset of the hardware, the Service Action Allowed and the Service
Action Required LEDs come on while the hardware is initializing. The seven-segment display shows
a sequence of codes that are the same for E-Series hardware and not specific to the E5600SG
controller.
During boot-up, the Field Programmable Gate Array (FPGA) controls the functions and initialization
on the hardware.
Code
Indication
19
FPGA initialization.
68
FPGA initialization.
...
FPGA initialization.
This is a quick succession of codes.
AA
Platform BIOS booting.
FF
Bios boot-up complete.
This is an intermediate state before E5600SG controller initializes and manages LEDs
to indicate status.
After the AA and FF codes appear, either the normal boot-up codes appear or error codes appear.
Additionally, the Service Action Allowed and the Service Action Required LEDs are turned off.
Normal boot-up codes
These codes represent the normal boot-up events that occur in the appliance, in chronological order.
Code
Indication
HI
The master boot script has started.
PP
The platform FPGA firmware is checking for updates.
HP
The host interface card (HIC) is checking for updates.
RB
After firmware updates, the system is rebooting, if necessary.
FP
The firmware update checks have been completed. Starting the process (utmagent) to
communicate with and manage the E2700 controller. This process facilitates appliance
provisioning.
HE
The system is synchronizing with the E-Series operating system.
HC
The StorageGRID installation is being checked.
HO
Installation management and active interfacing are occurring.
HA
The Linux operating system and StorageGRID are running.
Installing the hardware | 31