3. To review error codes for the E2700 controller, see the E2700 controller documentation on the
Support Site.
Related references
E5600SG controller seven-segment display codes
Related information
NetApp Documentation: E2700 Series
E5600SG controller seven-segment display codes
The seven-segment display on the E5600SG controller shows status and error codes while the
appliance powers up and while the hardware is initializing. You can use these codes to determine
status and troubleshoot errors.
When reviewing status and error codes on the E5600SG controller, you should look at the following
types of codes:
General boot-up codes
Represent the standard boot-up events.
Normal boot-up codes
Represent the normal boot-up events that occur in the appliance.
Error codes
Indicate issues during the boot-up events.
StorageGRID controls only the following LEDs on the E5600SG controller and only after the
StorageGRID Appliance Installer has started:
•
Service Action Allowed LED
•
Service Action Required LED
•
Seven-segment display
The decimal points on the seven-segment display are not used by the StorageGRID appliance:
•
The upper decimal point adjacent to the least significant digit is the platform diagnostic LED.
This is turned on during reset and initial hardware configuration. Otherwise, it is turned off.
•
The lower decimal point adjacent to the most significant digit is turned off.
30 | Hardware Installation and Maintenance Guide for SG5600 Appliances