36
Function: this interface is mainly used to calibrate nozzles’ positions.
P.S. Password is required to activate the items to avoid misoperation, please contact technical engineer before
calibrating.
1.Fiducial Camera Relative Position
Steps:
●Put a cooling pad on PCB, click “Rails 2” and fix the PCB on rails.
● Go to the Manual Test interface, move the head to make the nozzles stay above the cooling pad, then click “Nozzle 1
Trail” and “Back”.
●Go to the System Setup interface, ”click to align” on Fiducial Camera Relative Position.A prompt window will pop
up, ”If continue to leave trace at current position?“ After clicking ”Yes” to enter this interface (see Figure ), then click
“Nozzle 1 Trail”, the nozzle will move downwards and rotate until get a round mark. Follow the same steps to get the trail
of Nozzle #8 , then check the offset between the round mark and the white crosshair, if it’s within 0.1mm, the trail is done.
P.S. If the offset is overly beyond 0.1mm, please kindly contact NeoDen support team.
Mark Left Position: to use the left camera align the round mark
Mark Right Position:to use the right camera align the round mark
Exit: exit without operation
Save: save the date after operation
Zhejiang
NeoDen Technology Co.,Ltd.
Содержание K1830
Страница 6: ...1 3Working Area Structure Figure 3 Top view of main mounting area 6 Zhejiang NeoDen Technology Co Ltd ...
Страница 7: ...Figure 4 X axis Beam Figure 5 Main Placement Head Camera 7 Zhejiang NeoDen Technology Co Ltd ...
Страница 35: ...8 2 Component Positions Setup 35 Zhejiang NeoDen Technology Co Ltd ...
Страница 44: ...11 Structure and maintenance instruction 11 1 Feeder Brief Introduction 44 Zhejiang NeoDen Technology Co Ltd ...