background image

 

Installation Guide

 

6/29/2023

 

7

 

Permeate Pump Installation

 

1.

 

It may be necessary to trim tubing to ensure 
a proper fit of pump in the bracket with out 
ports on top.

 

2.

 

The permeate pump snaps into the black 
mounting clip already assembled to the 
bottom of the mounting bracket between the 
pre and post filter housings.  (#3 above)  
Orient the pump so the OUT ports are at the 
top (12:00) after the pump is snapped into 
the bracket.

 

3.

 

Locate the blue tubing hanging between the 
housings that is attached to the ASO (Auto 
Shut

-

Off)  Push the stem elbow on the other 

end into the PERMEATE OUT port.  The other 
blue tube will connect to the PERMEATE IN 
port

 

4.

 

Locate the red tubing hanging between the 
two housings that is connected to the 
membrane housing and flow restrictor.  This 
connects to the BRINE IN port.  Once the air 
gap faucet is installed, the red 

1/4” 

tube from 

the faucet air gap attaches to the BRINE OUT 
port.  

 

#3

 

Permeate Pump 

 

Auto Shut

-

Off

 

To Air Gap

 

Flow  
Restrictor

 

OUT 

 

 

IN

 

Mounting Clip

 

Outlet Elbow Assembly

 

The post filter outlet requires the stem adapter and elbow be installed.  
These parts are in the install kit bag to avoid shipping damage.  

 

1.

 

Apply 3

-

4 wraps of Teflon tape to the threaded end of the stem adapter 

and screw into the threaded port of the post filter be carful to not over 
tighten.

 

2.

 

Once the stem adapter is securely in place, push the elbow onto the stem 
so the collet is all the way down on the stem

 

Содержание PRO-41000-A Series

Страница 1: ...Installation Guide 6 29 2023 1 The High Efficiency Reverse Osmosis Drinking Water System Installation Operation and Service Manual PRO 41000 A Series...

Страница 2: ...embly Installation 7 Component Location Diagram 8 System Component and Replacements 9 Drain Saddle Location Description 10 Drain Saddle and Feed Supply Installation 11 Airgap Faucet Installation 12 Fi...

Страница 3: ...ke sure you understand the location and installation requirements of the air gap faucet that came with the system Water Quality In order for the system to function properly it is important to make sur...

Страница 4: ...membrane is a specially constructed fully aromatic polyamide film and is classified as a Thin Film Composite TFC The spiral wound construction of the RO Membrane provides maximum surface area for wate...

Страница 5: ...ate Pump Auto Shut Off Flow Restrictor Installation Kit Components Tubing for connection to water supply tank faucet and drain Feed supply adapter Drain saddle clamp Stem adapter and elbow fitting for...

Страница 6: ...the cap from the housing 2 Insert the membrane o ring end first with the brine seal on the cap end Push it in all the way 3 Replace the housing cap and reconnect the feed supply tubing Each membrane o...

Страница 7: ...connect to the PERMEATE IN port 4 Locate the red tubing hanging between the two housings that is connected to the membrane housing and flow restrictor This connects to the BRINE IN port Once the air g...

Страница 8: ...cet prior to installing it Then feed the tubes down through the installation hole for the faucet Finish the faucet mount and connect the tubing to the following 1 1 4 Red tube goes on the small barb o...

Страница 9: ...D Membrane FR 650 JG Flow Restrictor 75 Feed water To Faucet To Tank To Airgap Remineralizer Membrane Post Filter Pre Filter Permeate Pump Auto Shut Off Flow Restrictor To Remote Hook up Ice maker or...

Страница 10: ...he clamp tighten it then drill the hole Be careful not to damage the tube connection fitting Rotation can also occur over time if your system under the sink gets bumped Use a horizontal mount to minim...

Страница 11: ...d to fit 3 8 compression supply threads and has adapters for 1 2 NPS connections 1 Locate the cold water supply valve shut off under the sink Turn off the cold water supply 2 Turn on the kitchen fauce...

Страница 12: ...t ribs support brackets or other under sink construction CAUTION To prevent eye injury safety glasses must be worn during sink drilling operation Review components shown in Air Gap Faucet diagram Figu...

Страница 13: ...ure the tubing is pushed all the way in If uncertain measure 3 4 and mark the end of the tube It is pushed in all the way if the line disappears into the fitting If tubing is in far enough and still l...

Страница 14: ...ay intermittently spurt from the air gap opening on the side of air gap faucets This is common and should correct itself after the air is purged from the system CAUTION Ensure that the system is not b...

Страница 15: ...cated in the top of the filter housing and lubricated with silicon based lube 8 Insert the new Filter into the housing and rotate the housing back on to the cap clockwise Be careful to allow the top o...

Страница 16: ...o fill Most systems will be full within 2 3 hours depending on feed pressure membrane output and tank size The system is full when the water to the drain stops Check for leaks with the system full and...

Страница 17: ...4 from the non valved insert 2 Shake as much water as you can from the tube 3 Fill the syringe with the liquid sanitizer and empty it into the coupling body 4 so that it enters the tank through the tu...

Страница 18: ...water is out adjust the empty tank air pressure to 5 7 psi Reinstall the tank under the sink and turn feedwater back on an allow the tank to fill Carbon post filter is clogged Replace filter Tank val...

Страница 19: ...n any defective component You must pay any labor charges You must also pay for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover...

Страница 20: ...Installation Guide 6 29 2023 20...

Отзывы: