background image

 

Installation Guide

 

6/29/2023

 

19

 

Neo

-

Pure PRO

-

41000A Series Limited Warranty

 

What Does This Warranty Cover?

 This warranty covers any defects in materials and workmanship of the Neo

-

Pure® PRO

-

41000A Series High Efficiency Reverse Osmosis Drinking Water System when installed and 

operated within recommended parameters, with the exceptions stated below. 

 

How Long Does the Coverage Last?

 NeoLogic Solutions will warrant its R.O. Drinking Water System (except 

for the reverse osmosis membrane), for a period of five years from the date of purchase. The reverse 
osmosis membrane is warranted for one year from date of purchase. All implied warranties including 
merchantability and fitness for a particular purpose are limited to five years from the date of purchase for 
the R.O. Drinking Water System, except for the reverse osmosis membrane which is limited to one year from 
date of purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above 
limitations may not apply to you. 

 

What Will NeoLogic Solutions Do?

 NeoLogic Solutions will repair or replace at its discretion any defective 

component. You must pay any labor charges. You must also pay for shipping or travel charges to return the 
defective part(s). 

 

What Does This Warranty Not Cover?

 This warranty does not cover the disposable sediment and carbon 

filters whose service life depends on feed water conditions. In addition, the membrane is only warranted if 
the required feed water conditions are met. 

 

The above warranty will also not apply to any part of the Neo

-

Pure R.O. Drinking Water System that is 

damaged because of neglect, misuse, alterations, accident, misapplication, physical damage, or damage 
caused by fire, acts of God, freezing or hot waters or similar causes. Consequential and incidental damages 
are not recoverable under this warranty. Some states do not allow the exclusion or limitation of incidental or 
consequential damages, so the above limitation or exclusion may not apply to you. 

 

We recommend that you use only authorized Neo

-

Pure replacement parts since improper parts or 

incorrectly performed maintenance or repair voids this warranty. In addition, if non Neo

-

Pure parts are used, 

contaminant reduction claims and/or state approvals are no longer valid. 

 

How Does State Law Apply?

 This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

 

Содержание PRO-41000-A Series

Страница 1: ...Installation Guide 6 29 2023 1 The High Efficiency Reverse Osmosis Drinking Water System Installation Operation and Service Manual PRO 41000 A Series...

Страница 2: ...embly Installation 7 Component Location Diagram 8 System Component and Replacements 9 Drain Saddle Location Description 10 Drain Saddle and Feed Supply Installation 11 Airgap Faucet Installation 12 Fi...

Страница 3: ...ke sure you understand the location and installation requirements of the air gap faucet that came with the system Water Quality In order for the system to function properly it is important to make sur...

Страница 4: ...membrane is a specially constructed fully aromatic polyamide film and is classified as a Thin Film Composite TFC The spiral wound construction of the RO Membrane provides maximum surface area for wate...

Страница 5: ...ate Pump Auto Shut Off Flow Restrictor Installation Kit Components Tubing for connection to water supply tank faucet and drain Feed supply adapter Drain saddle clamp Stem adapter and elbow fitting for...

Страница 6: ...the cap from the housing 2 Insert the membrane o ring end first with the brine seal on the cap end Push it in all the way 3 Replace the housing cap and reconnect the feed supply tubing Each membrane o...

Страница 7: ...connect to the PERMEATE IN port 4 Locate the red tubing hanging between the two housings that is connected to the membrane housing and flow restrictor This connects to the BRINE IN port Once the air g...

Страница 8: ...cet prior to installing it Then feed the tubes down through the installation hole for the faucet Finish the faucet mount and connect the tubing to the following 1 1 4 Red tube goes on the small barb o...

Страница 9: ...D Membrane FR 650 JG Flow Restrictor 75 Feed water To Faucet To Tank To Airgap Remineralizer Membrane Post Filter Pre Filter Permeate Pump Auto Shut Off Flow Restrictor To Remote Hook up Ice maker or...

Страница 10: ...he clamp tighten it then drill the hole Be careful not to damage the tube connection fitting Rotation can also occur over time if your system under the sink gets bumped Use a horizontal mount to minim...

Страница 11: ...d to fit 3 8 compression supply threads and has adapters for 1 2 NPS connections 1 Locate the cold water supply valve shut off under the sink Turn off the cold water supply 2 Turn on the kitchen fauce...

Страница 12: ...t ribs support brackets or other under sink construction CAUTION To prevent eye injury safety glasses must be worn during sink drilling operation Review components shown in Air Gap Faucet diagram Figu...

Страница 13: ...ure the tubing is pushed all the way in If uncertain measure 3 4 and mark the end of the tube It is pushed in all the way if the line disappears into the fitting If tubing is in far enough and still l...

Страница 14: ...ay intermittently spurt from the air gap opening on the side of air gap faucets This is common and should correct itself after the air is purged from the system CAUTION Ensure that the system is not b...

Страница 15: ...cated in the top of the filter housing and lubricated with silicon based lube 8 Insert the new Filter into the housing and rotate the housing back on to the cap clockwise Be careful to allow the top o...

Страница 16: ...o fill Most systems will be full within 2 3 hours depending on feed pressure membrane output and tank size The system is full when the water to the drain stops Check for leaks with the system full and...

Страница 17: ...4 from the non valved insert 2 Shake as much water as you can from the tube 3 Fill the syringe with the liquid sanitizer and empty it into the coupling body 4 so that it enters the tank through the tu...

Страница 18: ...water is out adjust the empty tank air pressure to 5 7 psi Reinstall the tank under the sink and turn feedwater back on an allow the tank to fill Carbon post filter is clogged Replace filter Tank val...

Страница 19: ...n any defective component You must pay any labor charges You must also pay for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover...

Страница 20: ...Installation Guide 6 29 2023 20...