background image

WARNING

ATTENTION

Potential Electrostatic Charging Hazard
Risque potentiel de charge électrostatique 

Avoid electrostatic discharge :

• Clean exterior lens surface with damp cloth only

• Éviter les décharges électrostatiques: nettoyer la surface extérieure 

   de la lentille uniquement avec un chiffon humide

TM

Nemalux

I N D U S T R I A L

AR Series

rev. A-30

2-16

www.nemalux.com  |   [email protected]  |   Tel 403•242•7475  |   Fax 403•243•6190 

MADE IN CANADA

Electrical Rating:

      General Location       (ARXX-XXX-XX-XX-GN-XX), 

      Food Safe                    (ARXX-XXX-XX-XX-FS-XX),

      Hazardous Location  (ARXX-XXX-XX-XX-HZ-XX)

APPLICATION CONT.

General Location High Intensity model 

(ARXXH-XXX-XX-XX-GN-XX)

Temperature Range:

      

      General Location (ARXX-XXX-XX-XX-GN-XX)                             

      Food Safe              (ARXX-XXX-XX-XX-FS-XX) 

General Location High Intensity model 

(ARXXH-XXX-XX-XX-GN-XX)

Hazardous Location   (ARXX-XXX-XX-XX-HZ-XX)

LUMINANCE

AR10 

AR15 

AR20 

AR25 

AR30

RATED VOLTAGE

[Volts]

RATED WATTAGE

[Watts]

INPUT

VOLTAGE

AC

HV

AC

HV

AC

HV

AC

HV

AC

HV

120-277
347-480
120-277
347-480
120-277
347-480
120-277
347-480
120-277
347-480

107
129
145
145
190
187
247
248
312
310

FREQUENCY

[Hz]

50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60

LUMINANCE

AR20H 

AR25H

AR30H 

AR35H

AR40H

AR45H

AR50H

RATED VOLTAGE

[Volts]

RATED WATTAGE

[Watts]

INPUT

VOLTAGE

AC

HV

AC

HV

AC

HV

AC

HV

AC

HV

AC

HV

AC

HV

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

130
130
150
150
190
190
210
210
250
250
275
275
290
290

FREQUENCY

[Hz]

50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60

LUMINANCE

AR10, AR15, 

AR20, AR25 

AR30

AMBIENT TEMP

[

°C

]

INPUT

VOLTAGE

AC

HV

AC,HV Optical

AC Flood

HV Flood

-40

 to 55

-40

 to 50

-40

 to 45

-40

 to 40

-40

 to 45

LUMINANCE

AR20H,  AR25H

AR30H, AR40H

AR45H, AR50H

AMBIENT TEMP

[

°C

]

INPUT

VOLTAGE

AC

HV

AC

HV

AC

HV

-40

 to 53

-40

 to 48

-40

 to 49

-40

 to 40

-40

 to 42

-40

 to 40

LUMINANCE

AR10,  AR15, 

AR20

AR25

AR30

AMBIENT TEMP

[

°C

]

INPUT

VOLTAGE

AC

HV

AC

HV

AC

HV

-40

 to 55

-40

 to 54

-40

 to 51

-40

 to 44

-40

 to 43

-40

 to 43

AMBIENT TEMP

[

°C

]

CLASS I, DIV 2

T-CODES

T3C
T3C
T3C
T3B

T3
T3

-40 to 55
-40

 to 51

-40

 to 55

-40

 to 50

-40

 to 42

-40

 to 40

CLASS II, DIV 2

T-CODES

CLASS I, DIV 2

T-CODES

T4A

T4

T4A
T4A
T4A

T3

T5
T5
T5
T5
T5
T5

ALL MODELS

OPTICAL MODELS

FLOOD MODELS

To reduce the risk of electric shock, 

disconnect the luminaire from the 

supply circuit before opening for 

installation and servicing.  Keep 

tightly closed when in operation.

WARNING / ATTENTION

  

To avoid the risk of fire, explosion, 

or electric shock, this product 

should be installed, inspected, 

and maintained by a qualified 

electrician only, in accordance 

with all applicable electrical 

codes.

Éviter tout risque d'incendie, 

d'explosion ou d'électrocution, ce

produit doit être installé, inspecté et 

entretenu par un électricien qualifié 

uniquement, conformément à tous

codes électriques applicables.

WARNING / ATTENTION

Pour réduire le risque de choc 

électrique, débranchez le luminaire 

du circuit d'alimentation avant 

l'ouverture pour l'installation et 

entretien. Gardez hermétiquement 

fermé pendant le fonctionnement.

CURRENT

[A]

1.0A/0.5A
1.0A/0.5A
1.3A/0.6A
1.3A/0.6A
1.5A/0.7A
1.5A/0.7A
1.7A/0.8A
1.7A/0.8A
2.0A/0.9A
2.0A/0.9A
2.3A/1.0A
2.3A/1.0A
2.4A/1.0A
2.4A/1.0A

Содержание AR Series

Страница 1: ...proved Locations Class I Division 2 Groups ABCD T4 Class II Division 2 Groups FG T4A Class III Class I Zone 2 Group IIC Zone 22 Certifications NSF models ARXX XXX XX XX FS XX NSF ANSI 2 Splash and Non...

Страница 2: ...0 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 LUMINANCE AR10 AR15 AR20 AR25 AR30 AMBIENT TEMP C INPUT VOLTAGE AC HV AC HV Optical AC Flood HV Flood 40 to 55 40 to 50 40 to 45 40 to 40...

Страница 3: ...hors to the 12 7mm 0 5 holes Suspension hardware Not provided must be rated for a minimum of 180 lbs STEP 4 Open AR Lens with a 7mm socket or wrench and allow Lens to hang via retention strap Note Scr...

Страница 4: ...ontrol needs 0 10V Controller must sink current from LED driver 0 10V control connections Dimming controls must be certified and suitable for the classification of the area of their installation NOTE...

Страница 5: ...a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure STEP 5 Insert and tension M6...

Страница 6: ...M6 bolts and washers and adhesive backed gasket Apply gasket to mount with adhesive backed side Torque to 5 Nm 45 in lbs STEP 5 Install Back Cover Plate with 4x M4 Flat head screws and adhesive backe...

Страница 7: ...sed thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure STEP 3 Loosely assemble Yoke mount with carriage bolts on inside and washer...

Страница 8: ...all hook assembly into NPT threaded entry Tighten to hand tight plus 1 to 2 turns Slide anti rotation lock into place and tighten set screw to lock unit in place NOTE To aid in assembly and protection...

Страница 9: ...stem must be rated for 180 lbs NOTE To aid in assembly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit open...

Страница 10: ...embly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of...

Страница 11: ...stall and prevent loss of fasteners STEP 3 Install provided double sided tape along side of surge protector Remove backing paper and place between mounting points as shown with tape side down Install...

Страница 12: ...ector to splice or terminal connected to Black leads from LED Drivers 3 Connect White lead from surge protector to splice or terminal connected to Neutral Input branch circuit conductor and White lead...

Страница 13: ...nd ensure surge protector is held tightly in place STEP 4 Wire according to wiring instructions on Page 2 Refer to NEC CEC codes and follow all applicable local standards STEP 5 Close AR lens Ensure t...

Страница 14: ...LED Drivers 3 Disconnect Neutral Input branch circuit conductor from splice or terminal connected to White leads from LED Driver Re connect Neutral Input branch circuit conductorto Yellow wire from su...

Страница 15: ...G ATTENTION INSTALLATION STEPS AR SFY SLIP FITTER YOKE MOUNT Ordered Separately This AR SFY kit is intended for use with UL Listed AR luminaire as marked on the luminaire nameplate Accessory Package C...

Страница 16: ...hain to fixed eye bolt not supplied using the second stainless steel oval shaped threaded connecting link Alternate attachment method Wrap loose end of chain around fixed beam or other immovable suppo...

Отзывы: