WARNING
ATTENTION
Potential Electrostatic Charging Hazard
Risque potentiel de charge électrostatique
Avoid electrostatic discharge :
• Clean exterior lens surface with damp cloth only
• Éviter les décharges électrostatiques: nettoyer la surface extérieure
de la lentille uniquement avec un chiffon humide
TM
Nemalux
I N D U S T R I A L
AR Series
rev. A-30
2-16
www.nemalux.com | [email protected] | Tel 403•242•7475 | Fax 403•243•6190
MADE IN CANADA
Electrical Rating:
General Location (ARXX-XXX-XX-XX-GN-XX),
Food Safe (ARXX-XXX-XX-XX-FS-XX),
Hazardous Location (ARXX-XXX-XX-XX-HZ-XX)
APPLICATION CONT.
General Location High Intensity model
(ARXXH-XXX-XX-XX-GN-XX)
Temperature Range:
General Location (ARXX-XXX-XX-XX-GN-XX)
Food Safe (ARXX-XXX-XX-XX-FS-XX)
General Location High Intensity model
(ARXXH-XXX-XX-XX-GN-XX)
Hazardous Location (ARXX-XXX-XX-XX-HZ-XX)
LUMINANCE
AR10
AR15
AR20
AR25
AR30
RATED VOLTAGE
[Volts]
RATED WATTAGE
[Watts]
INPUT
VOLTAGE
AC
HV
AC
HV
AC
HV
AC
HV
AC
HV
120-277
347-480
120-277
347-480
120-277
347-480
120-277
347-480
120-277
347-480
107
129
145
145
190
187
247
248
312
310
FREQUENCY
[Hz]
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
LUMINANCE
AR20H
AR25H
AR30H
AR35H
AR40H
AR45H
AR50H
RATED VOLTAGE
[Volts]
RATED WATTAGE
[Watts]
INPUT
VOLTAGE
AC
HV
AC
HV
AC
HV
AC
HV
AC
HV
AC
HV
AC
HV
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
130
130
150
150
190
190
210
210
250
250
275
275
290
290
FREQUENCY
[Hz]
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
LUMINANCE
AR10, AR15,
AR20, AR25
AR30
AMBIENT TEMP
[
°C
]
INPUT
VOLTAGE
AC
HV
AC,HV Optical
AC Flood
HV Flood
-40
to 55
-40
to 50
-40
to 45
-40
to 40
-40
to 45
LUMINANCE
AR20H, AR25H
AR30H, AR40H
AR45H, AR50H
AMBIENT TEMP
[
°C
]
INPUT
VOLTAGE
AC
HV
AC
HV
AC
HV
-40
to 53
-40
to 48
-40
to 49
-40
to 40
-40
to 42
-40
to 40
LUMINANCE
AR10, AR15,
AR20
AR25
AR30
AMBIENT TEMP
[
°C
]
INPUT
VOLTAGE
AC
HV
AC
HV
AC
HV
-40
to 55
-40
to 54
-40
to 51
-40
to 44
-40
to 43
-40
to 43
AMBIENT TEMP
[
°C
]
CLASS I, DIV 2
T-CODES
T3C
T3C
T3C
T3B
T3
T3
-40 to 55
-40
to 51
-40
to 55
-40
to 50
-40
to 42
-40
to 40
CLASS II, DIV 2
T-CODES
CLASS I, DIV 2
T-CODES
T4A
T4
T4A
T4A
T4A
T3
T5
T5
T5
T5
T5
T5
ALL MODELS
OPTICAL MODELS
FLOOD MODELS
To reduce the risk of electric shock,
disconnect the luminaire from the
supply circuit before opening for
installation and servicing. Keep
tightly closed when in operation.
WARNING / ATTENTION
To avoid the risk of fire, explosion,
or electric shock, this product
should be installed, inspected,
and maintained by a qualified
electrician only, in accordance
with all applicable electrical
codes.
Éviter tout risque d'incendie,
d'explosion ou d'électrocution, ce
produit doit être installé, inspecté et
entretenu par un électricien qualifié
uniquement, conformément à tous
codes électriques applicables.
WARNING / ATTENTION
Pour réduire le risque de choc
électrique, débranchez le luminaire
du circuit d'alimentation avant
l'ouverture pour l'installation et
entretien. Gardez hermétiquement
fermé pendant le fonctionnement.
CURRENT
[A]
1.0A/0.5A
1.0A/0.5A
1.3A/0.6A
1.3A/0.6A
1.5A/0.7A
1.5A/0.7A
1.7A/0.8A
1.7A/0.8A
2.0A/0.9A
2.0A/0.9A
2.3A/1.0A
2.3A/1.0A
2.4A/1.0A
2.4A/1.0A