11-16
www.nemalux.com | [email protected] | Tel 403•242•7475 | Fax 403•243•6190
MADE IN CANADA
TM
Nemalux
I N D U S T R I A L
AR Series
rev. A-30
AR-SP-AC – SURGE SUPPRESSOR KIT (Ordered Separately)
(Requires AR-SP-AC Surge Protector Accessory Kit)
• Protects against surges and transients per ANSI C62.41-2002 category
C high (10KV, 1.2/50μS & 10KA, 8/20μS) standard Combo waves and
(6KV, 100KHz) Ring wave
• Protects against surges and transients per new ANSI C82.77-5 2015
category C high (20KV, 1.2/50μS & 10KA, 8/20μS) standard Combo
waves and (6KV, 100KHz) Ring wave.
STEP 1.
Inspect shipping package and contents to ensure no damage has
occurred during shipping.
STEP 2.
Open AR Lens with 7mm hex socket driver. Allow Lens to hang via
retention strap.
NOTE:
Screws are captive fasteners and will remain attached to the Lens for
ease of reinstall and prevent loss of fasteners.
STEP 3.
Install provided double-sided tape along side of surge protector.
Remove backing paper and place between mounting points as shown,
with tape-side down. Install retention strap with two M3 fasteners and
ensure surge protector is held tightly in place.
STEP 4.
Wire according to wiring instructions on Page 2. Refer to NEC/CEC
codes and follow all applicable local standards.
STEP 5.
Close AR lens. Ensure the retention cable is not pinched between AR
Head and the AR Lens. Tighten lens bolts using a 7mm socket or box
wrench to 1.7 N-m (15 in-lbs) in the order designated in the diagram to
ensure gasket sealing.
5
6
7
8
9
10
11
12
1
2
3
4
Step 5
AR-SP-AC
PART NAME
QTY
1
1
1
2
2
FSP3-277-20KA SURGE PROTECTOR
3M VHB TAPE
SURGE SUPPRESSOR RETENTION STRAP
M3 x 8mm PAN HEAD PHILLIPS MACHINE SCREW
M3 FLAT WASHER
Step 3
M3 SCREW
This AR-SP-AC kit is intended for use with UL Listed AR luminaire as
marked on the luminaire nameplate.
Accessory Package Contents
INSTALLATION STEPS