AR-WM – WALL MOUNT INSTALLATION (Ordered Separately)
Refer to alternate instructions if using Conduit, Hook, Pole, Yoke Mount, or High Vibration Yoke
STEP 1.
Inspect shipping package and contents to ensure no damage has occurred
during shipping. Discard surface/ceiling mounting bracket provided with AR
luminaire. Remove 4 x M6 bolts from supply side of luminaire and disard.
STEP 2.
Install provided 3/4 NPT conduit plugs in desired locations on wall mount.
To maintain ingress rating all NPT entries not used for wiring connections are
required to be plugged. Torque to 10 Nm (88 in-lbs)
NOTE:
To aid in assembly and protection against ingress use of a petrolatum or
soap thickened mineral oil based thread lubricant/sealant is necessary.
Un-used conduit opening must be plugged to maintain the integrity of the
enclosure.
STEP 3.
Install provided 3/4” NPT plastic bushing onto side NPT entry on AR head,
rotate so that flats are parallel to lens surface to avoid interference with
mount hardware.
STEP 4.
Install Wall Mount main body with included M6 bolts and washers and
adhesive backed gasket. Apply gasket to mount with adhesive backed side.
Torque to 5 Nm (45 in-lbs).
STEP 5.
Install Back Cover Plate with 4x M4 Flat head screws and adhesive backed
gasket. Apply gasket with adhesive side applied to mount main body.
Torque to 1.7 N-m (15 in-lbs).
STEP 6.
Mount luminaire assembly to desired location using
4x 1/4-20 OR M6 Screws or Bolts (Not Provided).
STEP 7.
Resume installation instructions provided with luminaire.
(STEP 4 in AR Installation Instructions provided with Luminaire)
Steps 2 through 5
[5.7in]
145mm
4 x 6.8mm THRU
ALL
[5.7in]
145mm
Step 6
This AR-WM kit is intended for use with UL Listed AR luminaire as
marked on the luminaire nameplate.
Accessory Package Contents
AR-WM
PART NAME
QTY
1
1
1
1
4
4
4
3
1
WALL MOUNT
WALL MOUNT PLATE
WALL MOUNT PLATE SIDE GASKET
WALL MOUNT GASKET
6 x 25mm SOCKET HEAD CAP SCREW
M4x 10mm FLAT HEAD SOCKET CAP SCREW
M6 FLAT WASHER
3/4 NPT HEX CAP PLUG
3/4 NPT THREADED SMOOTH BORE BUSHING
INSTALLATION STEPS
WARNING:
The AR Head must not face
upwards by any degree
beyond the vertical position
for Class II, Division 2,
Zone 22, and Class III
hazardous locations.
LIGHT BEAM
HORIZON
ATTENTION:
Le luminaire (AR) ne doit pas
être orientée vers le haut de
quelque degré que ce soit
au-delà de la position verticale
pour les emplacements
dangereux de Classe II,
Division 2, Zone 22 et Classe III