User Manual of E Series Network Speed Dome
57
Manual Stops:
When manual limit stops are set, you can operate the PTZ control panel manually only in the
limited surveillance area.
Scan Stops:
When scan limit stops are set, the random scan, frame scan, auto scan, tilt scan, panorama
scan is performed only in the limited surveillance area.
Manual Stops
of
Limit Type
is prior to
Scan Stops.
When you set these two limit types at the
same time,
Manual Stops
is valid and
Scan Stops
is invalid.
3.
Click the PTZ control buttons to find the left/right/up/down limit stops; you can also call the
defined presets and set them as the limits of the speed dome.
4.
Click
Set
to save the limits or click
Clear
to clear the limits.
5.4.3
Configuring Initial Position
Purpose:
The initial position is the origin of PTZ coordinates. It can be the factory default initial position.
You can also customize the initial position according to your own demand.
Customize an Initial Position:
Steps:
1.
Enter the Initial Position Configuration interface:
Configuration
>
PTZ
>
Initial Position
Figure 5-28
PTZ Configuration
2.
Click the PTZ control buttons to find a position as the initial position of the speed dome; you
can also call a defined preset and set it as the initial position of the speed dome.