User Manual of E Series Network Speed Dome
49
2.
Check the
Enable Intrusion Detection
checkbox.
Figure 5-22
Configuring Intrusion Area
3.
The event triggered and park action related PTZ movement will be locked for 180 seconds
after you enter the intrusion detection interface. Optionally, you can click the
button to manually activate the movement, or lock the movement
when the button turns to
by clicking it.
4.
Draw area.
1)
Select the Region No.in dropdown list.
2)
Click
to draw a rectangle on the image as a defense region.
3)
Click on the image to specify a corner of the rectangle, and right-click the mouse after
four corners are configured.
Up to four areas are supported. You can click
to clear the areas you drawn.
5.
Configure the parameters for each defense region separately.
Threshold:
Range [0-10s], the threshold for the time of the object loitering in the region. If
you set the value as 0, alarm is triggered immediately after the object entering the region.
Sensitivity:
Range [1-100]. The value of the sensitivity defines the size of the object which
can trigger the alarm, when the sensitivity is high, a very small object can trigger the