© by N&W GLOBAL VENDING S.p.A.
39
10 2009 3325 - 00
STATISTICS
e
lecTronic
counTer
T
o
display
The
elecTronic
counTer
An electronic counter is intended to store all the dispens-
ing cycles you have performed since you last reset it in
an aggregated manner.
T
o
reseT
The
elecTronic
counTer
You can reset the electronic counter.
T
o
display
The
elecTronic
counTer
aT
The
sTarT
-
up
Function used to enable or disable the display of the
total number of dispensing cycles that have been sold
since you last reset the statistics, while you are powering
on the machine.
eva-dTs
Two codes are used to identify the machine and recog-
nise the data transfer terminal according to the EVADTS
(European Vending Association Data Transfer System)
communication protocol:
STATISTICS
EVA-DTS
DEX - UCS
DDCMP ENHANCED
TECHNICIAN> X.X
c
ommunicaTion
proTocol
Use this function to decide which communication proto-
col to use for the communication of the date acquisition
device.
Available communication protocols are listed here below:
ddcmp
enhanced
the following parameters can be configured:
-
Pass code
: it is a 4-digit alphanumeric code (0-9; A-F)
that must be the same as the one of the data transfer
terminal for identification purposes.
Set to 0000 by default.
-
Security code
: it is an alphanumeric code for mutual
recognition between the machine and the EVADTS
terminal.
Set to 0000 by default.
-
End of transmission
: if enabled, it can recognise the
end-of-transmission signal sent to the latest package
and interrupt data transmission.
dex
/
ucs
no parameter can be configured for this protocol:
d
aTa
Transmission
Function used to select which communication interface
to use for the data transfer. The following interfaces are
made available:
-“RS232” and “IrDA”: to dialogue with data acquisition
devices
-“ALWAYS EVADTS”: to dialogue with data acquisition
and transmission devices (telemetry)
T
ransmission
speed
(
BaudraTe
)
To set up the transmission speed in use for communica-
tion (2400, 4800, 9600, 19200 bps).
Set to 2400 bps by default.
c
onnecTion
If you activate this function, the machine will be waiting
for connection with a device in order to acquire EVADTS
data.
d
isplay
general
Press the Enter key
�
to display the data you have
stored in sequence, i.e.:
1 - counter by single selection;
2 - counter by band;
3 - discount counter;
4 - failure counter;
5 - coin mechanism data.
r
eseT
general
Statistics can be reset either globally (all types of data)
or selectively, i.e. by:
- selections
- discounts-overprices
- failures
- coin mechanism data
Press the Enter key
�
to display the request for confir
-
mation “Do you confirm?”
�
flashing on and off.
Press the Enter key to display the “Execution” message
for some seconds and to reset statistics.
d
isplay
relaTive
Press the Enter key
�
to display the data you have
stored in sequence, i.e.:
1 - counter by single selection;
2 - counter by band;
3 - discount counter;
4 - failure counter;
5 - coin mechanism data.