Configure the Xn120
34
Xn120 Getting Started Guide
Recall for Normal Telephones
You may want to change this setting if:
·
You have normal telephones connected and the RECALL key does not work correctly. This is
highlighted when you press the RECALL key but the call is not placed on hold.
·
The RECALL is also referred to as Timed Break Recall (TBR).
System Operation:
The Xn120 must be configured with the correct RECALL timing that matches the normal telephones that you
have connected.
Program 82-04-04
Set the system to detect a
RECALL duration of 70 to
125mS (for normal UK time
break recall operation).
You will need to change three
options within this program.
82-04-04=13
82-04-07=14
82-04-08=25
Default Setting:
The Xn120 will accept a RECALL duration of 105mS to 1000mS
Ø
Change the setting to 13 (this is equivalent to 65mS).
Ø
Press HOLD 3 times to confirm the entry and step to the next
option.
Ø
Change the setting to 14 (this is equivalent to 70mS).
Ø
Press HOLD to confirm the entry and step to the next option.
Ø
Change the setting to 25 (this is equivalent to 125mS).
Ø
Press HOLD to confirm the entry and step to the next option.
Ø
Press DC several times when you are done to return to the
Program Mode.
Ø
(Press SPK to save changes and exit if you are finished).
Configuration Sheet: RECALL Timing
With defaults shown.
82-04-04
default=20
(100mS)
82-04-07
default=22
(105mS)
82-04-08
default=200
(1000mS)
Setting
Equivalent
duration (mS)
82-04-04
Max.Break TM 13
82-04-07
Max.Break TM 14
82-04-08
Max.Break TM 25