July 2003
NEC Business Solutions Ltd
62 – A16
Authorisation Code
Doc. No. 8
201 - Re
lease 1.0
July 2003
5.
Press
N
to enter the information. The next Account Number
is displayed. Repeat steps 4~5 until all desired Account Codes
are entered.
6.
Press
P
to stop entering Forced Account Codes/Authorisation
Codes.
SERVICE
CONDITIONS
Verified or Unverified for the Forced Account Code/Authorisation Code
features.
Memory Block 1-8-08 (Class of Service (Station) Feature Selection 2),
Page 6, LK 3 is used to activate assign Verified or Unverified for the
Forced Account Code/Authorisation Code features.
When a call is made without using an authorisation code, memory
blocks 4-64 and 4-65 are used to assign the code restriction class.
When a call is made using an authorisation code, the code restriction
class is temporarily changed and Memory Blocks 4-07 and 4-08 are
used to assign the code restriction class.
After placing a call using an authorisation code, if the Recall or Drop
keys are used, the temporary code restriction class remains with the
setting assigned in Memory Blocks 4-07 and 4-08 allowing the user to
dial another non-restricted number.
After placing a call using an authorisation code, when the station goes
idle (On-hook), the code restriction class is reset to its previous setting
assigned in Memory Blocks 4-64 and 4-65.
A total of 500 Forced Account Codes/Authorisation Codes can be
entered system-wide.
Forced Account Codes/Authorisation Codes and Account Code entries
Codes are printed on the SMDR report, if both are used.
A
is placed in front of the Forced Account Codes/Authorisation
Codes on the SMDR reports to distinguish them from other Account
Code entries.
When the Interdigit time (default is 10 seconds) expires during the user
input of a Forced Account Codes/Authorisation Code, Busy Tone is
generated.
PBR Time values apply when a Single line Telephone is used to enter
a Forced Account Code/Authorisation Code.
Forced Account Codes/Authorisation Codes can be uploaded,
downloaded, or modified using PC-based System Programming.
Restrictions
A Forced Account Code/Authorisation Code has a maximum of
13 digits.
The Authorisation Code feature is only provided from intercom dial
tone. Direct access to trunks is bypassed by pressing CO Line Keys.