Xen IPK
Features and Specifications Manual
Features and Specifications Manual
U3 – 601
D
oc. N
o. 8201 -
Release
1.0
July 20
03
Refer to the Xen IPK System Hardware Manual for more information.
Restrictions
KSU Power-Based ETU Quantity Limitations
The following charts indicate the maximum number of specific ETU
combinations in each KSU that are restricted by power limitations of
the KSU.
Application Interface
Units
Description
Maximum Capacities
Notes
Basic Port
Package
Expanded
Port Package
BSU(2)-U( ) ETU
2-Channel - Base Station Unit for PHS
3
8
DPH(4)-U( ) ETU
4-Channel - Door Phone Interface Unit
1
1
ECR-U( ) ETU
External Control Relay Unit
1
1
MIFA-U( ) ETU
Multiple Interface Unit for UCD/ACD
1
1
Note 1, 3
MIFM-U( ) ETU
Multiple Interface Unit for Multifunction
1
1
Note 1, 2, 3
PBR( )-U( ) ETU
4-Channel - Push Button Receiver Unit
1
1
VRS(4)-U( ) ETU
4-Channel - Voice Recording Service
Unit
2
2
NOTE 1:
The MIFM-U( ) or MIFA-U( ) ETU must be installed in the ISA slot, slot 1, or slot 2 of the first B64-U( )
KSU.
NOTE 2:
The MIFM-U( ) ETU has an optional built-in modem that works only when the The MIFM-U( ) ETU is
installed in slot 1 or slot 2 of the first B64-U( ) KSU.
NOTE 3:
The MIFA-U( ) ETU (with KMA( )UA installed) has an ACD-MIS output that works only when the
MIFA-U( ) ETU is installed in the ISA slot. When ACD-MIS and remote MAT PC programming are
required, install the MIFA-U( ) ETU in the ISA slot and the MIFM-U( ) ETU in slot S1 or slot S2 of the
first B64-U( ) KSU.
*NO. of
ESI(8) ETUs
NO. of
ESI Ports
Maximum NO. of
ACD+/FMS/VMS/IPT/
SLI/OPX or DID ETUs
Other ETUs
10
80
2
No Limitation
9
72
2
No Limitation
8
64
3
No Limitation
7
56
4
No Limitation
6
48
5
No Limitation
5
40
5
No Limitation
4
32
6
No Limitation
3
24
6
No Limitation
2
16
7
No Limitation
1
8
7
No Limitation