CHAPTER 9 WATCHDOG TIMER FUNCTIONS
Preliminary User’s Manual U15905EJ1V0UD
278
9.4
Operation
9.4.1
Operation as watchdog timer
Watchdog timer operation to detect a program loop is selected by setting bit 4 (WDTM4) of the watchdog timer
mode register (WDTM) to 1.
The count clock (program loop detection time interval) of the watchdog timer can be selected with bits WDCS0 to
WDCS2 of the watchdog timer clock selection register (WDCS). The count operation is started by setting bit 7 (RUN)
of the WDTM register to 1. When, after the count operation is started, the RUN bit is again set to 1 within the set
program loop detection time interval, the watchdog timer is cleared and the count operation starts again.
If the program loop detection time is exceeded without the RUN bit being set to 1, a reset (WDTRES) or a non-
maskable interrupt request signal (INTWDT) is generated, depending on the value of bit WDTM3 of the WDTM
register.
The count operation of the watchdog timer stops in the software STOP mode and IDLE mode. Therefore, set the
RUN bit to 1 before the software STOP mode or IDLE mode is entered in order to clear the watchdog timer.
Because the watchdog timer operates in the HALT mode, do not use the watchdog timer when using the HALT
mode.
Caution
Once the WDTM4 bit is cleared to 0 (thereby selecting the interval timer mode), the watchdog
timer mode is not entered as long as RESET is not input.
When the subclock is selected for the CPU clock, the count operation of the watchdog timer
stops (the value of the watchdog timer is maintained).
Table 9-2. Program Loop Detection Time of Watchdog Timer
Program Loop Detection Time
Clock
f
X
= 17 MHz
f
X
= 13.5 MHz
f
XX
= 8 MHz
2
14
/f
X
964
µ
s
1.214 ms
2.048 ms
2
15
/f
X
1.928 ms
2.427 ms
4.096 ms
2
16
/f
X
3.855 ms
4.855 ms
8.192 ms
2
17
/f
X
7.710 ms
9.709 ms
16.38 ms
2
18
/f
X
15.42 ms
19.42 ms
32.77 ms
2
19
/f
X
30.84 ms
33.84 ms
65.54 ms
2
20
/f
X
61.68 ms
77.67 ms
131.1 ms
2
22
/f
X
246.7 ms
310.7 ms
524.3 ms
Remark
f
XW
= f
X
: Watchdog timer clock frequency