Chapter 1 CCIS FEATURES
1-77
NWA-088654-001 Rev.1.0
94ch1003.fm
BUSY LAMP FIELD (BLF)-CCIS
• For BLF message receiving office (Office B, C)
DESCRIPTION
DATA
Provide Busy Lamp Field (BLF)-CCIS to each
CCH number.
•
(1)
(2)
Y=30
00-63: CCH No.
0: To provide
To the virtual Port number, assign the station
number of the other office which is accommo-
dated to the BLF, as follows.
For closed numbering system: station number
For open numbering system: Access code + of-
fice station number
(1)
(2)
0000-0999: Virtual Port No.
X-XXXXXXXX: Station No.
NOTE:
Amount of Access Code + Office
No. + Station No. must be no
more than 8 digits.
Specify whether the station number assigned
by CM11 is own office station or the other of-
fice station
•
(1)
(2)
Y=40
X-XXXXXXXX: Station No. assigned by
CM11
0 : Other office station
1 : Own office station
Assign the station number of the other office to
the keys on the DSS Console.
(1)
(2)
DSS Console No. (00-31) +
+ DSS Key
No. (00-59)
X-XXXXXXXX: Station No. assigned by
CM11
START
CMA7
CM11
CM13
CM97
,
A