Chapter 1 CCIS FEATURES
1-43
NWA-088654-001 Rev.1.0
94ch1002.fm
CCIS BASIC PROGRAMMING
DESCRIPTION
DATA
Assign the trunk number to be used as the com-
mon signaling channel.
•
(1)
(2)
Y=00
00-63: CCH No.
000-511: Trunk No. assigned by CM10
Y=00
Assign an Originating Point Code (OPC) to
each CCH number.
NOTE:
The Originating Point Code is used
to designate an originating office in
the No. 7 CCIS network. A single
OPC should be assigned to all CCH
numbers provided in the same sys-
tem.
•
(1)
(2)
Y=01
00-63: CCH No.
00001-16367: Originating Point Code
Assign a Destination Point Code (DPC) to
each CCH number.
NOTE:
The Destination Point Code is used
to designate a terminating office in
the No. 7 CCIS network. Usually a
different DPC is assigned to each
CCH number in the same system.
•
(1)
(2)
Y=02
00-63: CCH No.
00001-16367: DPC
Assign the Point Code of the Centralized Fault
Reporting office, if required.
•
(1)
(2)
Y=05
00-63: CCH No.
00001-16367: Point Code of Centralized
Fault Reporting office
Assign the originating office number to each
CCH number, if required.
NOTE:
This data setting is required only for
open numbering system.
•
(1)
(2)
Y=06
00-63: CCH No.
0000-9999: Originating Office No.