Chapter 1 CCIS FEATURES
1-39
NWA-088654-001 Rev.1.0
94ch1002.fm
CCIS BASIC PROGRAMMING
DESCRIPTION
DATA
Assign the necessary functions to each CCT.
NOTE 1:
This command is only applicable for
the 24CCT.
NOTE 2:
The following table shows the rela-
tionship between CMAA Y=01 and
Y=02.
[ ] indicates 2nd Data
•
(1)
(2)
Y=00 Data Mode
NOTE 1, NOTE 2
000-127: Trunk Blade No. assigned by
CM05 Y=1
1: Based on AT&T Specifications
•
(1)
(2)
Y=02 Zero Code Suppression [B7]
NOTE 1, NOTE 2
000-127: Trunk Blade No. assigned by
CM05 Y=1
0 : Available (Non Transparent)
1 : Not available (Transparent)
•
(1)
(2)
Y=19 Selection of cable length for CCT
000-127: Trunk Blade No. assigned by
CM05 Y=1
0 : 0-40 m (0-131.2 ft.)
1 : 41-81 m (134.5-265.7 ft.)
2 : 82-122 m (269-400.2 ft.)
3 : 123-162 m (400.4-531.4 ft.)
4 : 163-200 m (534.8-656 ft.)
7 : 0-40 m (0-131.2 ft.)
•
(1)
(2)
Y=20 Short/Long mode setting of cable
(CCT)
000-127: Trunk Blade No. assigned by
CM05 Y=1
0 : Short distance
1 : Long distance
A
CMAA
CMAA Y=01
(FRAME
CONFIGURATION)
CMAA Y=02
(ZERO CODE
SUPPRESSION)
SIGNALING
24-Multi Frame
[1]
B8ZS
12-Multi Frame
[0]
Not available
[1]
Transparent
Available
[0]
B7
BLADE RESET
BLADE RESET
B