Chapter 2 Q-SIG FEATURES
2-13
NWA-088654-001 Rev.1.0
94ch2001.fm
PRT ASSIGNMENT
DESCRIPTION
DATA
Specify the cable length for PRT.
•
(1)
(2)
Y=19
000-127: Trunk blade No. assigned by
CM05 Y=1
0 : 0-40 m (0-131.2 ft.)
1 : 41-81 m (134.5-265.7 ft.)
2 : 82-122 m (269.0-400.2 ft.)
3 : 123-162 m (403.4-531.4 ft.)
4 : 163-200 m (534.6-656 ft.)
7 : 0-40 m (0-131.2 ft.)
Assign a Q-SIG trunk number to the PRT
blade.
•
(1)
(2)
Y=00
XX YY ZZ: Physical Port No.
XX: 01-50: Unit No.
YY: 01-18: Slot No.
ZZ : 01-23: Circuit No. (B ch) of 24 PRT
24: Circuit No. (D ch) of 24 PRT
ZZ : 01-15, 17-31: Circuit No. (B ch) of 30
PRT
16: Circuit No. (D ch) of 30
PRT
D000-D511: Trunk No.
Assign the destination to receive the synchro-
nous signal for PRT.
•
(1)
(2)
Y=10-59
01: First priority
02: Second priority
01-18: Slot No.
NOTE 1:
This data is assigned for the clock synchronization of SV9300 for the opposite office of
ISDN network/CCIS/Digital Tie Line. Do not assign this data for ISDN terminals.
NOTE 2:
The second data must be assigned the Slot number to which each interface blade (PRT/
BRT/CCT/DTI) is accommodated (the first data 01 [first priority] is mandatory. Do not as-
sign the first data 02 [second priority] only).
NOTE 3:
The connection to a SIP conversion adapter with BRT/PRT blade depends on whether the
adapter can supply the clock or not. Do not assign this data for the BRT/PRT blade when
the clock cannot be supplied.
A
CMAA
BLADE RESET
CM10
BLADE RESET
CM04
BLADE RESET
B