
Chapter 3 REMOTE UNIT OVER IP FEATURES
3-22
NWA-088654-001 Rev.1.0
94ch3001.fm
SYSTEM SETUP
(2) Procedure for an Additional Remote Unit Installation
STEP1:
Assign all required system data to the CPU blade of Main Unit, including the required data for
Remote Unit.
STEP2:
Load all License Activation data to the Main Unit.
For details, refer to License Activation Operation Guide.
[For other than North America]
STEP3:
Execute the system data backup to the Flash ROM of CPU blade by CMEC Y=6>0: 0.
STEP4:
Set the SENSE switch of #0 CPU to “E” (Off-line), and push the RESET switch of #0 CPU.
STEP5:
Clear the system memory of Remote Unit by CM00>1.
STEP6:
Assign the IP address of Main Unit and own IP address to the CPU blade of Remote Unit to be
additionally installed.
STEP7:
Assign own Unit number to the CPU blade of Remote Unit to be additionally installed by
CM0B Y=000>90
STEP8:
Execute the system data backup to the Flash ROM of CPU blade of Remote Unit.
STEP9:
Set the SENSE switch of #0 CPU to “1” (on-line), and push the RESET switch of #0 CPU.
STEP10:
Confirm that the link between Main Unit and Remote Unit is established.
If not, connect the Main Unit and Remote Unit by LAN.
– The required system data is copied to the Remote Unit from the Main Unit. It takes 3-4 min-
utes to copy the system data from the Main Unit to the Remote Unit.
– The Remote Unit starts.