Chapter 3 REMOTE UNIT OVER IP FEATURES
3-49
NWA-088654-001 Rev.1.0
94ch3001.fm
LIST OF COMMANDS
The table below shows the required command list and the data setting procedure that are set to the CPU
blade of Remote Unit in the sample system.
NOTE:
Some cells are colored in order to see the table easily.
Command List Set to Remote Unit
Setting Procedure
CM
Y
1st
Data
2nd Data
Remarks
Reference
Page
No.
Contents of Setting
1
System data memory all clear
00
1
CCC
Refer to
System
Manual
2
Unit number for Remote Unit
0B
000
90
05
3
IP address for Main Unit
(VoIPDB)
0B
101
00
172.16.1.1
Unit No.=01
4
Subnet Mask for Main Unit
(VoIPDB)
0B
101
01
255.255.255.000
5
Default Gateway address for
Main Unit (VoIPDB)
0B
101
02
172.16.1.254
6
IP address for Remote Unit
(ETHERNET)
0B
005
00
192.168.2.1
Remote Unit No.=05
Refer to
Command
Manual
7
Subnet Mask for Remote Unit
(ETHERNET)
0B
005
01
255.255.255.0
8
IP address for Remote Unit
(VoIPDB)
0B
105
00
172.16.2.1
Remote Unit No.=05
9
Subnet Mask for Remote Unit
(VoIPDB)
0B
105
01
255.255.255.000
10
Default Gateway address for
Remote Unit (VoIPDB)
0B
105
02
172.16.2.254
11
Registration of VoIPDB (RTP)
in Main Unit
0B
201
00
172.16.1.2
IP Address of VoIPDB
(RTP)
12
Registration of VoIPDB (RTP)
in Remote Unit
0B
205
00
172.16.2.5
IP Address of VoIPDB
(RTP)
13
System Data Backup
EC
6
0
0
Data Backup to Flash
Rom of CPU blade
Refer to
System
Manual
OFF LINE
OFF LINE