General Description
This feature provides an indication on external equipment when the CCIS link is connected/disconnected,
when the system is initialized.
Programming
DESCRIPTION
DATA
Assign a Unit and Slot number to the DLC
blade.
NOTE:
When the PGD(2)-U10 ADP is
accommodated to the Remote Unit,
execute the system data copy by
CMEC Y=8 before executing the
blade reset.
•
(1)
(2)
Y=0
XX ZZ
XX: 01-50: Unit No.
ZZ : 01-18: Slot No.
10: DLC blade
Assign the station number connected to
PGD(2)-U10 ADP to its associated Physical
Port number.
•
(1)
(2)
Y=00
XX YY ZZ: Physical Port No.
XX: 01-50: Unit No.
YY: 01-18: Slot No.
ZZ : 01-32: Circuit No.
X-XXXXXXXX: Station No.
Assign the Kind of PGD(2)-U10 station.
NOTE 1:
Set the second data to “1” when
combining external relay with pag-
ing. Set the second data to “3” only
when using this feature.
NOTE 2:
When this command is set, PGD(2)-
U10 needs to reset (Blade Reset or
pull out and reconnect the modular
connector of the Multiline Termi-
nal).
•
(1)
(2)
Y=65
X-XXXXXXXX: Station No.
1: Paging
3: External relay/External key/External
Hold Tone Source/Voice Response Sys-
tem
START
CM05
BLADE RESET
CM10
CM12
A