Program 41 : ACD Setup
41-13 : VRS Message Number for Night Announcement
Level:
SA
Description
Use
Program 41-13 : VRS Message Number for Night Announcement
to define the VRS message
number to use as the night announcement. This program is activated when the night announcement
source is assigned as VRS in Program 41-12-01.
Input Data
ACD Group No.
1 ~ 8
Item
No.
Item
Input Data
Description
Default
01
VRS Message Num-
ber
0 ~ 100
0 = No Message
Input the VRS message number to be
used as the night announcement.
0
02
Tone Kind at Message
Interval
0 = Ring Back Tone
1 = MOH Tone
2 = BGM Source
Input what is heard between the Night An-
nouncements.
0
Conditions
None
Feature Cross Reference
• Automatic Call Distribution (ACD)
SL2100
ISSUE 1.0