91
7. Appendix
7-8. PC Control Codes and Cable Connection
PC Control Codes
Function
Code Data
POWER
ON
02H 00H 00H 00H 00H 02H
POWER
OFF
02H 01H 00H 00H 00H 03H
INPUT
SELECT
HDMI
1
02H 03H 00H 00H 02H 01H A1H A9H
INPUT
SELECT
HDMI
2
02H 03H 00H 00H 02H 01H A2H AAH
INPUT
SELECT
COMPUTER
02H 03H 00H 00H 02H 01H 01H 09H
INPUT
SELECT
BNC
02H 03H 00H 00H 02H 01H 02H 10H
INPUT
SELECT
DVI-D
02H 03H 00H 00H 02H 01H 9CH A4H
INPUT
SELECT
DisplayPort
02H 03H 00H 00H 02H 01H A6H AEH
INPUT
SELECT
SDI
02H 03H 00H 00H 02H 01H C4H CCH
INPUT
SELECT
HDBaseT
02H 03H 00H 00H 02H 01H BFH C7H
NOTE:
• Contact your local dealer for a full list of the PC Control Codes if needed.
Cable Connection
Communication Protocol
Baud rate
9600 bps
Data length
8 bits
Parity
No parity
Stop bit
One bit
X on/off
None
Communications procedure
Full duplex
NOTE:
• Depending on the equipment, a lower baud rate may be recommended for long cable runs.
PC Control Terminal (D-SUB 9P)
1
5
2
4
3
6 7
9
8
To GND of PC
To RxD of PC
To TxD of PC
To RTS of PC
To CTS of PC
NOTE:
• Pins 1, 4, 6 and 9 are no used.
• Jumper “Request to Send” and “Clear to Send” together on both ends of the cable to simplify cable connection.