5-10 Disassembly and Reassembly
6.
Replace the front bezel (see “Front Bezel”).
7.
Replace the system unit top cover (see “System Unit Top Cover”).
8.
Connect the power cord and monitor and peripheral cables.
EMI Clip (Riser Card)
This subsection describes how to remove and replace the EMI clip.
Removal
To remove the EMI clip, proceed as follows:
1.
Turn off the system and disconnect the power cord and all peripheral cables
connected to the system.
2.
Remove the system unit top cover (see “System Unit Top Cover”).
3.
Remove the front bezel (see “Front Bezel”).
4.
Separate the two halves of the chassis (see “Opening the System Chassis” in
Section 3).
5.
Remove the system board and riser card (see “System Board” and “Riser Card”).
6.
Pry the clip (see Figure 5-6) off the riser card. Save the clip for reinstallation.
Replacement
To replace the EMI clip, proceed as follows:
1.
Complete steps 1 through 6 in the previous subsection.
2.
Locate the solder pad and hole in the end of the riser card closest to the network
connector.
3.
Slide the clip on the solder pad onto the riser card until the dimple on the clip
engages in the hole in the riser card (see Figure 5-6).