92
Appendix
5-3. Remote Interlock Connector
This connector functions as safety device for the projector. The contacts are normally closed. When an abnormality occurs, the
contacts open to immediately stop the projector (interlock state) (shipped with a shorting wire installed). By replacing the shorting
wire with wiring and attaching it to the contacts, the projector can be immediately stopped remotely when an abnormality occurs in
the projector.
Follow the following procedure to recover from the interlock state.
1
Disconnect the AC power supply to the projector body.
2
Remove the front cover (page 26).
3
Connect the contacts to the remote interlock connector and attach the front cover.
4
Connect the AC power supply to the projector body.
Remote interlock connector (exterior view)
#1
#2
#3
#4
Shorting wire 1
Shorting wire 2
•
The remote interlock terminal is equipped on inside of the front cover.
Remove the front cover for connection.
•
Securely reinstall the front cover.