90
Appendix
Error Code
Error message
Description
574
IMB:Security Tamper
Security tamper condition exists in IMB.
577
IMB:Security Battery Event
A Battery Tamper event has been detected with the IMB.
581
IMB:Security Enclosure Not Armed
IMB security not armed.
582
IMB:Physical Marriage Tamper
The IMB has detected a break of the Marriage with the
projector.
583
IMB:Logical Marriage Tamper
The IMB has detected an error with the verification of the
Marriage with the projector.
584
IMB:Marriage NOT Active
The IMB has not established a marriage with the projector
586
IMB:Service Door Tamper
Latched service door tamper condition on IMB
588
IMB:Security Battery Low Warning
Close to “(577) IMB: Security Battery Event”.
700
OPT Comm Fail
Failed to communicate with Opt CPU
701
OPT Status Fail
Opt CPU is in unexpected status.
702
Lamp Lit Change
Any one Lamp of the two Lamps is off.
703
OPT Comm Ack Fail
Opt CPU fails to execute the command.
704
LampOff Fail
Failed to lamp off
710
Lamp1 OverTime
Lamp1 cumulative time is over.
711
Lamp2 OverTime
Lamp2 cumulative time is over.
720
Lamp1 Door Open(Warning)
Lamp1 door (cover) is open while HotSwap is enabled.
721
Lamp2 Door Open(Warning)
Lamp2 door (cover) is open while HotSwap is enabled.
740
SensorFail Inlet1
Failed to read inlet sensor 1.
741
SensorFail DMD
Failed to read DMD sensor.
750
OverTemp.DMD Precaution
Set inside temperature (DMD) is close to over temperature.
751
OverTemp.Inlet1 Precaution
Set inside temperature (Inlet) is close to over temperature.
752
Down Lamp Power Activated
Down lamp power to decrease set inside temperature.
753
OverTemp.Ballast1 Precaution
Set inside temperature (Ballast1) is close to over
temperature.
754
OverTemp.Ballast2 Precaution
Set inside temperature (Ballast2) is close to over
temperature.
760
OverTemp.DMD
Set inside temperature (DMD) is abnormal.
761
OverTemp.Inlet1
Set inside temperature (Inlet) is abnormal.
762
OverTemp.Lamp
Set inside temperature (Lamp) is abnormal.
764
OverTemp.Ballast1
Set inside temperature (Ballast1) is abnormal.
765
OverTemp.Ballast2
Set inside temperature (Ballast2) is abnormal.
781
Interlock Open
Interlock is open.
782
SystemI2cFail
Failed to control sensors connecting to GPIO chip.
(Slave board internal abnormality)
783
EepromFail
Slave MCU failed to read back all of data from EEPROM on
slave MCU board due to unexpected data or something.
(Slave board internal abnormality)
785
SoftwareI2cFail
I2C/UART conversion chip control failed on slave board.
(Slave board internal abnormality)
786
PreCooling
Failed to precool.
787
Lamp1 Door Open
Lamp1 door (cover) is open.
788
Lamp2 Door Open
Lamp2 door (cover) is open.
789
Ballast1UartError
Communication error between slave MCU and ballast1.
790
Ballast2UartError
Communication error between slave MCU and ballast2.
791
FanInitError
Failed to initialize fans.
792
ExGpioFail
Failed to control the signal connecting to Ballast.
(Slave board internal abnormality)
793
Notch Filter Open
Notch Filter Cover is open.
794
Inlet2 Sensor
Failed to read inlet sensor 2.
800
Fan15 Stop
Fan15 has stopped.
801
Fan16 Stop
Fan16 has stopped.