Troubleshooting 8-19
Problems with Express Setup
Following message appeared when you tried to install Express Setup to the hard disk drive
that has smaller capacity than the specified partition size:
The creating of the partition was failed.
The process can not be continued. The process was stopped.
O
K
→
Cannot continue the setup.
Specify smaller partition size than the capacity of connected hard disk drive, and then
retry the setup.
Express Setup terminated and asks to input setup information.
→
There are some errors on the specified setup information.
Follow the instruction to input the correct value. It is not necessary to cancel the
installation.
The system partition is created by size smaller than specified value.
→
In ExpressSetup, there are some cases that the system partition is created by size
about 8MB smaller than specified size.
It is not a problem in operating the system.
Specified to join the Domain, but the system is installed as Workgroup.
→
When the setup fails to join the Domain during the installation, it will install the
system as Workgroup. Open [System] in Control Panel to specify joining the Domain.
Changed the giga driver speed from 1000M bps to 100M bps. But the changed speed is not
properly displayed in Network Details of NEC ESMPRO DataViewer (still 1000M bps is
indicated):
→
It does not affect the operation of LAN driver.
Fail to start Parameter File Creator:
→
Parameter File Creator requires to run by "Microsoft(R) HTML Application host".
If Parameter File Creator does not start, associate the file type with "Microsoft(R)
HTML Application host" via following process.
1) Click [Run] on Start menu.
2) Type "%windir%\system32\mshta.exe /register" in the [Open] box, and click
[OK].
Содержание N8100-1447F
Страница 31: ...General Description 2 5 Rear View 1 2 3 2 4 5 6 7 8 9 10 12 11 13...
Страница 48: ...2 22 General Description This page is intentionally left blank...
Страница 157: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear...
Страница 216: ...9 6 Upgrading Your Server 3 Loosen the two screws 4 Hold the side cover securely to remove it...
Страница 217: ...Upgrading Your Server 9 7 5 Position the server until on its right side...
Страница 256: ...9 46 Upgrading Your Server This page is intentionally left blank...
Страница 266: ...10 10 Internal Cabling Diagrams This page is intentionally left blank...
Страница 268: ...A 2 Specifications This page is intentionally left blank...
Страница 276: ...C 2 IRQ This page is intentionally left blank...
Страница 328: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Страница 332: ...G 4 Product Configuration Record Table This page is intentionally left blank...