- 14 -
●
Precautions for Using EXPRESSSCOPE Engine 3, NEC ESMPRO
Manager or ROM Utility
(1) Power threshold setting value
The power threshold setting value can be checked by following the steps below.
■
EXPRESSSCOPE Engine 3 :
[Configuration]
→
[BMC]
→
[ECO]
■
NEC ESMPRO Manager : [Remote Control]
→
[Electric Power Management]
→
[ECO Setting]
→
[Power Capping]
■
ROM Utility :
Turn on the power of the server and the following message appears at the lower left of
the screen.
Press <F2> to enter SETUP, <F4> ROM Utility, <F12> Network
Press the <F4> key to enter ROM Utility.
Select [KB_Select]
→
[BMC Configuration]
→
[BMC Configuration]
→
[ECO]
→
[Configuration].
For the following settings, a value that is higher than the power of the power unit you purchased
can be specified, however, specify a value lower than the recommended values listed below.
·
The [Power Threshold (Pa)] setting value for
[Aggressive Mode] in the edit screen mode
·
The [Power Threshold (Pn)] setting value for [Non-Aggressive Mode] in the edit screen mode
The recommended setting values for the power units are as follows.
N8100-1954F/1956F Express5800/R120d-1E (450W)
:
Lower than 530W
N8151-1955F Express5800/R120d-1E (800W)
:
Lower than 920W
N8100-1950F Express5800/R120d-2E (450W)
:
Lower than 530W
N8151-1951F/1952F/1953F Express5800/R120d-2E (800W)
:
Lower than 920W
Ex.) Screenshot of EXPRESSSCOPE Engine 3