background image

G4-Apex-ENTERPRISE-

HW

Hardware Installation

30 Apr 2021

Summary of Contents for G4-Apex-ENTERPRISE-HW

Page 1: ...G4 Apex ENTERPRISE HW Hardware Installation 30 Apr 2021 ...

Page 2: ...put voltage 100V 240V Auto Select Operational current amps 5 15 BTU hr 2109 Operational voltage 120V Power dissipation watts 618 Relative humidity non condensing 8 to 90 Temperature operating 10 C 35 C 50 F 95 F Temperature storage 40 C to 60 C 40 F to 140 F Compliance RoHS FCC CE 1 For SFP the SFP may be any of Copper 10 100 1000 1Gb SX LX For SFP the SFP may be any of 10Gb SR LR For QSFP the QSP...

Page 3: ...e appliance is very heavy Always use a server lift or work with a partner to install or remove the appliance from the cabinet to perform any maintenance 1 Mount the appliance in your cabinet Refer to the instructions on VIAVI Rail Kit page 7 Do not remove the drives from the chassis 2 Connect the cables Power Ethernet Intelligent Platform Management Interface IPMI optional 3 Connect the KVM 4 Set ...

Page 4: ... channel for device maintenance It allows you to monitor start stop and manage your appliance remotely regardless of whether the appliance is powered on 5 Connect a monitor keyboard and mouse to the hardware appliance You can use a KVM switch if desired The KVM must be compatible with the operating system used on the appliance The user input devices or KVM switch are only temporarily needed to set...

Page 5: ...ol Version 4 TCP IPv4 and click Properties 3 Set the IP address subnet mask router or gateway and DNS server for your environment and click OK 4 Click OK again to close the Properties dialog for that network connection You interact with the hardware appliance through the Apex UI 1 Navigate to https hostname where hostname is the IP address or DNS name for the appliance 2 Log into the interface usi...

Page 6: ...er account ADMIN account 10 Click Modify User and change the password 11 Optional Set up alerts There is no audible alarm if there is an issue with a power supply unit Other alerting options are available Each must be configured separately using details from your environment To receive email alerts change the settings at Configuration SMTP To receive SNMP traps change the settings at Configuration...

Page 7: ...rd so that it will fit with the rack s mounting bracket 3 Slide the rail toward the front of the chassis to hook the inner rail onto the side of the chassis 4 Optional If desired secure the rail with two flat head M4 x 4mm screws and washers as illustrated 5 Repeat for the other inner rail 6 Identify the outer rack rails 7 Press upward on the locking tab at the rear end of the middle rail 8 Push t...

Page 8: ...sistance supporting the chassis when removing it from the rack Use a server lift 1 Pull the chassis forward out the front of the rack until it stops 2 Press the release latches on each of the inner rails downward simultaneously and move the chassis forward in the rack Technical Support Please contact technical support if your issues are not represented or you need further help North America 1 800 ...