Configuring Your Server 4-39
7.
Press
F10
to create virtual drive.
The "Virtual Drives Configure" screen appears. (The figure below shows an example of
RAID1 configured with two hard disk drives.)
8.
Select "RAID," "Size", "DWC", "RA", or "Span" by using cursor keys. Then press
Enter
to fix the selection and set each value.
(1) "RAID": Sets RAID level.
Parameter
Remarks
0
RAID0
1
RAID1
10
Striping of RAID1
The selectable RAID level varies depending on the number of hard disk drives
that configure a pack.
(2) "Size": Sets virtual drive size.
Up to 8 virtual drives can be created per RAID Controller.
(3) "DWC": Sets parameter for Disk Write Cache.
Parameter
Remarks
Off
Write through
On *
1
Write back
*1 Recommended setting.
"Write-back On" enables good performance, however, cache data may be lost at
an unexpected power failure. "Write-back Off" reduces performance by
approximately 50%.
(4) "RA": Sets parameter for Read Ahead.
Parameter
Remarks
Off
Does not perform read ahead.
On
Performs read ahead. (Recommended)
Содержание Express5800/iR120a-1E
Страница 16: ...x This page is intentionally left blank ...
Страница 19: ...Notes on Using Your Server 1 3 2 5 inch Hard Disk Drive Model Attached to the bottom of the chassis ...
Страница 34: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Страница 67: ...Setting Up Your Server 3 13 4 To remove the rail assembly pull out the rail toward you while pushing the lever ...
Страница 158: ...5 30 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete ...
Страница 256: ...8 12 Installing and Using Utilities This page is intentionally left blank ...
Страница 268: ...9 12 Maintenance This page is intentionally left blank ...
Страница 372: ...C 2 IRQ This page is intentionally left blank ...
Страница 374: ...D 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 378: ...E 4 Product Configuration Record Table This page is intentionally left blank ...