7-46 Upgrading your Server
Removal
Remove the DIMM using the following procedure.
NOTES:
!
To remove the failed DIMM, check the error message appearing in
POST or ESMPRO to identify the DIMM socket (group) in which the
failed DIMM is installed.
!
The server operates only when at least two DIMMs are installed.
1.
See the section
Preparing for Upgrade
described earlier to prepare.
2.
Remove the left-hand side access panel as described earlier in this chapter.
3.
Remove the top air duct.
4.
Open the levers at both sides of the socket from which you remove the DIMM.
The DIMM is unlocked and ready for removal.
5.
Reinstall all parts removed in Step 2 and 3.
Power on the server and verify that POST displays no error messages.
If POST displays an error message, write down the message and see the POST error
messages listed in Chapter 6.
6.
Start the SETUP and select [Advanced]
→
[Memory Configuration]
→
[Memory Retest]
→
[Enabled] to clear the error information of the removed DIMM. (See Chapter 3 for
details.)
7.
Select "Yes" for [Reset Configuration Data] on the Advanced menu.
This setting is required to change the hardware configuration data. See Chapter 3 for
details.
Содержание EXPRESS5800/120MF
Страница 1: ... EXPRESS5800 120Mf U s e r s G u i d e ...
Страница 2: ......
Страница 4: ......
Страница 12: ...x ...
Страница 24: ...1 6 System Overview Rear View 11 9 10 12 13 14 15 16 2 17 15 18 17 16 1 8 7 6 1 2 3 4 5 2 5 1 ...
Страница 58: ...1 40 System Overview This page is intentionally left blank ...
Страница 59: ...Chapter 2 Setting Up Your Server This chapter describes how to set up your server ...
Страница 202: ...4 62 Installing the Operating System and Utilities This page is intentionally left blank ...
Страница 214: ...5 12 Maintenance This page is intentionally left blank ...
Страница 229: ...Troubleshooting 6 15 Memory modules DIMM Group 3 DIMM Group 2 DIMM Group 1 ...
Страница 282: ...7 28 Upgrading your Server Removal Follow the installation instructions in reverse order to remove the backup device ...
Страница 304: ...7 50 Upgrading your Server This page is intentionally left blank ...
Страница 305: ...Chapter 8 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Страница 318: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...
Страница 326: ...C 8 Installing Windows 2000 This page is intentionally left blank ...
Страница 340: ...10 Glossary This page is intentionally left blank ...
Страница 345: ...xx ...
Страница 346: ... ...