8-20 Troubleshooting
Problems with Windows
There are some cases that an event log is registered as follows when you install Windows
Server 2003 x64 Editions.
Source:
DCOM
Category:
Error
Event ID:
10016
Description: The application-specific permission settings do not grant Local Activation
permission for the COM server application with CLSID {555F3418-D99E-
4E51-800A-6E89CFD8B1D7} to the user {NT AUTHORITY\LOCAL
SERVICE} SID {S-1-5-19}.
This security permission can be modified using the component Services
administrative tool.
→
It is not a problem in operating the system.
There are some cases that an event log is registered as follows when you install Windows
Server 2003 x64 Editions.
Event Source: Service Control Manager
Event Type:
Error
Event ID:
7011
Description:
Timeout (30000 milliseconds) waiting for a transaction response from the
IMAP4Svc service.
→
When this event is not registered by rebooting the system, it is not a problem in
operating the system.
There are some cases that an event log is registered as follows when you operate Windows
Server 2003 R2.
Source:
IPMIDRV
Type:
Error
Event ID:
1001
Description: The IPMI device driver attempted to determine if the system supported an
IPMI BMC device. The driver attempted to detect the presence of the IPMI
BMC by searching the SMBIOS for Type 38 record. But either no record was
found or the record was not compatible with the version of the device driver.
If a SMBIOS Type 38 record was detected, the Dump Data field of the event
contains a binary representation of the record.
→
If you use "Hardware Management" which is provided by Windows Server 2003
R2, above-shown event log will be registered.
For more details, refer to "Enabling Microsoft Windows Server 2003 R2
Hardware Management" on the following site.
[NEC Express5800 Web Site]
http://www.nec.co.jp/express/download/W2K3_R2
Содержание Express5800/120Lj
Страница 16: ...x This page is intentionally left blank ...
Страница 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15 ...
Страница 108: ...4 40 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 119: ...Configuring Your Server 4 51 Use this menu to define several physical drives PD as a disk group DG ...
Страница 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed ...
Страница 195: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 220: ...7 12 Maintenance This page is intentionally left blank ...
Страница 300: ...9 42 Upgrading Your Server Removal Remove the HDD cage in the reverse procedure of the installation ...
Страница 316: ...9 58 Upgrading Your Server Removal Remove the 5 25 inch device in the reverse procedure of the installation ...
Страница 352: ...9 94 Upgrading Your Server This page is intentionally left blank ...
Страница 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Страница 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank ...
Страница 362: ...A 2 Specifications This page is intentionally left blank ...
Страница 370: ...C 2 IRQ This page is intentionally left blank ...
Страница 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 430: ...G 4 Product Configuration Record Table This page is intentionally left blank ...