10-6 Internal Cabling Diagrams
Connection of Disk Array Controller (SCSI)
If SCSI disks are installed, the disk array controller can be connected to the server. The internal hard
disks can be subject to the disk array configuration. The supported RAID configuration includes
RAID0 (striping) and RAID1 (mirroring).
In addition, three hot-swap SCSI hard disk drives are accessible from the front of the chassis which
can be swapped in or out of the system without powering it down if the optional hot-swap SCSI
hard disk drive cage is installed in your system.
IMPORTANT:
The installed disk array controller in the server is used
only for configuring the RAID drive with the internal hard disk drives.
The disk array controller does not connect with the optional external
SCSI drive enclosure.
RAID0 (striping)
RAID0 provides block "striping" across multiple drives, yielding higher performance than
is possible with individual drives. This level does not provide any redundancy.
IMPORTANT:
If either of the two hard disks configuring the array is defected, the
data cannot be recovered.
The logical capacity of the array is an integer multiple of the
capacity of a connected hard disk.
RAID1 (mirroring)
The hard disk drives are paired and mirrored. All data is 100 percent duplicated on a drive
of equivalent size.
IMPORTANT:
Because data is read to or written from two hard disks concurrently,
the disk access performance is lower than that of the configuration
using only a single disk.
The logical capacity of the array is the same as the capacity of a
single hard disk connected.
Содержание Express5800/110Ei
Страница 1: ...N8100 1005F NEC Express5800 110Ei User s Guide 1st Edition 11 2004 ONL 3125aN 110Ei 100 99 0411 ...
Страница 16: ...x This page is intentionally left blank ...
Страница 33: ...General Description 2 5 Rear View 1 2 3 2 4 5 6 7 8 9 10 11 12 ...
Страница 104: ...4 42 Configuring Your Server This page is intentionally left blank ...
Страница 148: ...5 44 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 168: ...6 20 Installing and Using Utilities This page is intentionally left blank ...
Страница 180: ...7 12 Maintenance This page is intentionally left blank ...
Страница 218: ...9 8 Upgrading Your Server Secure the side cover with two screws removed in the removal procedure Screws ...
Страница 270: ...10 14 Internal Cabling Diagrams This page is intentionally left blank ...
Страница 272: ...A 2 Specifications This page is intentionally left blank ...
Страница 314: ...F 4 Product Configuration Record Table This page is intentionally left blank ...