2. Standard Features
Scalable Modular Server DX2000 User’s Guide
21
Chapter1 General Description
2.1
Management Features
The server modules and CSC modules (refer to
Chapter 1, 3.5
and
3.6
) in this server can be configured and
checked from a management terminal on the network, by using IPMI commands.
CSC modules
2.1.1
CSC modules are used to monitor and manage sensors (FAN, voltage, temperature and so on) of the chassis.
The management function provided by CSC modules is as follows.
Indication/setting item
Description
Property
General information
Information about items such as IP address, MAC address, and
firmware version
*1
Information of field
replaceable unit (FRU
information)
Information about items such as boards
*1
and chassis
System
Information about items such as UID LED and time
*1
Power supply
Control the power supplied to all server modules in the chassis
in a batch and check their status.
SEL (System Event Log)
Indicates SEL information.
Sensor Indicates
sensor information.
Alert receiver
Used to specify the alert receivers.
An example for using the
ipmitool
command is shown below.
For how to check the CSC’s IP address refer to
Chapter 3 (3.2 Obtaining IP Addresses for CSC module and
Switch Modules)
.
ipmitool -I lanplus -U Administrator -P Administrator –H [CSC IP address] [option]
Item
Command execution example (
option
)
IP address and MAC address
lan print
Firmware version
mc info
Displaying SEL information
sel list
Displaying sensor information
sensor
Checking the alert receiver
lan alert print
Turn on UID lamp
default setting of <interval> is 15 seconds.
Setting is “0”, UID lamp turn off.
chassis identify<interval>