Section 2: PCB Installation and Startup
2-48
◆
Section 2: PCB Installation and Startup
Aspire S Hardware Manual
10. Perform a Cold Start.
a.
Push in and hold the Load button.
b.
Power the system back up.
c.
Continue holding the Load button for approximately 3 seconds.
d.
Release the Load button.
e.
Allow the system to completely reload the software (approximately 2 minutes). The Status LED
(LD2) will be
fl
ashing on the CPU.
11. Reconnect to the system with PCPro and reload the database saved in Step 6
EXCEPT FOR PRO-
GRAMS 16-02, 11-07, 45-01, and all 47-xx.
Downloading the complete database will cause prob-
lems with the IntraMail programing.
a.
Click
COMMUNICATIONS - UPLOAD
.
b.
Under the
SELECT RANGE
drop-down box, select
SYSTEM CONFIGURATION
and click
START
.
c.
Once that upload is complete, under the
SELECT RANGE
drop-down box, select
SYSTEM
DATA.
While holding down the CTRL key, scroll to each program which should not be down-
loaded (11-07, 45-01, and all the 47-xx programs) and click to deselect. Click
START
d.
Once that upload is complete, under the
SELECT RANGE
drop-down box, select
TELE-
PHONE
DATA
. While holding down the CTRL key, scroll to Program 16-02 and click to dese-
lect. Click
START
e.
Once that upload is complete, under the
SELECT RANGE
drop-down box, select
VE DATA
and click
START
.
A screen may appear indicating there is no data to upload. Simply click
OK
and continue
with the next upload.
f.
Once that upload is complete, under the
SELECT RANGE
drop-down box, select
TRUNK
DATA
and click
START
.
g.
Click
CLOSE
.
12. Click
COMMUNICATIONS - DISCONNECT
to exit system programming.
Exiting programming mode could take a minute or more while it saves the database.
13. Wait until the Status LEDs on the CPU have the following indications (approximately 2 minutes), then
power the system down.
LD1: Flashing Red, LD3: Flashing Red, LD4: Flashing Red, LD2: Steady Green.
14. Reinstall the PCBs removed in Step 8.
15. Turn the system power back on.
Refer to the
Aspire IntraMail System Guide, Chapter 1 - Quick Setup
(P/N 0893240) for
details on programming the IntraMail feature.